ProNet series AC servo system User’s manual V.1.08
- 106 -
Adjust the analog reference offset manually in the following procedure.
1. Press the MODE key to select the utility function mode.
2. Press the INC or DEC key to select the utility function number Fn004.
3. Press the ENTER key to enter into the speed reference offset manual adjustment mode.
4. Turn ON the servo-ON signal, the display is shown as follows:
5. Hold the ENTER key for one second, the speed reference offset will be displayed.
6. Press the INC or DEC key to change the offset.
7. Hold the ENTER key for one second to return to the display in step 4.
8. Press ENTER key to return to the utility function mode display Fn004..
Thus, the speed reference offset manual adjustment is completed.