ProNet series AC servo system User’s manual V.1.08
- 108 -
■
Manual
Manual
Manual
Manual Offset-adjustment
Offset-adjustment
Offset-adjustment
Offset-adjustment of
of
of
of Servomotor
Servomotor
Servomotor
Servomotor Current
Current
Current
Current Detection
Detection
Detection
Detection Signal
Signal
Signal
Signal
Adjust the servomotor current detection signal manually in the following procedure.
1. Press the MODE key to select the utility function mode.
2. Press the INC or DEC key to select the utility function number Fn006.
3. Press the ENTER key to enter into the manual adjustment of the servomotor current detection signal
mode.
4. Press the MODE key to switch between the phase U(o _ CuA) and phase V(1_ Cub) servomotor
current detection offset adjustment.
5. Hold the ENTER key for one second to display the phase V offset amount.
6. Press the INC or DEC key to adjust the offset.
7. Press the ENTER key for one second to return to the display in step 3 or 4.
8. Press the ENTER key to return to the utility function mode display Fn006.
Thus, the manual offset-adjustment of the servomotor current detection signal is completed.
Note:
Note:
Note:
Note:
The adjusting range of the servomotor current detection offset is -1024 to +1024.