Appendix A
Parameter
- 133 -
A.2 Description of Parameter Type
Para
Para
Para
Para.... No.
No.
No.
No.
Name
Name
Name
Name
Unit
Unit
Unit
Unit
Setting
Setting
Setting
Setting
Range
Range
Range
Range
Factory
Factory
Factory
Factory
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Invalidation
Invalidation
Invalidation
Invalidation
Pn682
Programme mode
—
0~1
0
Immediately
Pn683
Programme start step
—
0~15
0
Immediately
Pn684
Programme stop step
—
0~15
1
Immediately
Pn685
Search travel speed
rpm
0~3000
1500
Immediately
Pn686
Leave travel switch speed
rpm
0~3000
30
Immediately
Pn687
Position teaching pulse
10000P
-9999~9999
0
Immediately
Pn688
Position teaching pulse
1P
-9999~9999
0
Immediately
Pn700
Hex
Hex
Hex
Hex
Pn700.0: MODBUS communication baud
rate
Pn700.1: MODBUS protocol selection
Pn700.2:Communication protocol selection
Pn700.3: Reserved
—
0~0x0182
0x0151
After restart
Pn701
MODBUS axis address
—
1~247
1
After restart
Pn840
Hex
Hex
Hex
Hex
Pn840.0
:
Encoder model selection
Pn840.1
:
Reserved
Pn840.2
:
Reserved
Pn840.3
:
Reserved
—
0
~
A
—
After restart
Type
Type
Type
Type
Parameter
Parameter
Parameter
Parameter No.
No.
No.
No.
Description
Description
Description
Description
Funtion selection switches
Pn000~Pn006
Control mode, stop mode, and some functions selection
Parameters of servo gain
Pn100~Pn129
Position gain, speed gain,rigidity,etc.
Position control related parameters
Pn200~Pn205
PG divided ratio, electronic gear, etc.
Speed control related parameters
Pn300~Pn312
Speed reference input, soft start, etc.
Torque control related parameters
Pn400~Pn406
Torque limit, etc.
Parameters to control I/O port
Pn500~Pn520
Allocation of I/O port function
Point-to-point control related parameters
Pn600~Pn686
Internal point-to-point control related parameters
Communication parameters
Pn700~Pn701
Setting of communication parameters