Chapter 2
Installation
- 19 -
■
■
■
■Installation
Installation
Installation
Installation Orientation
Orientation
Orientation
Orientation
Install servodrive perpendicular to the wall so that the front panel (containing connectors) faces
outward.
■
■
■
■Cooling
Cooling
Cooling
Cooling
Provide sufficient space around each servodrive to allow cooling by natural convection or fans.
■
■
■
■Installing
Installing
Installing
Installing side
side
side
side by
by
by
by side
side
side
side
When installing servodrives side by side, provide at least 10 mm space between them and at least
50 mm space above and below them as shown in the figure above. Make sure that the temperature
inside the control panel is evenly, and prevent the temperature around each servodrive from
increasing excessively. Install cooling fans above the servodrives if required.
■
■
■
■Working
Working
Working
Working conditions
conditions
conditions
conditions
1.Temperature
:
0~ 55
℃
2.Humidity
:
90%RH or less
3.Vibration
:
4.9m/s
2
or less
4.Ambient temperature to ensure long-term reliability: 45
℃
or less