ProNet series AC servo system User’s manual V.1.08
- 94 -
4.11 Other Output Signals
4.11.1 Rotation Detection Output Signal(/TGON)
·
Related
Related
Related
Related parameter
parameter
parameter
parameter
4.11.2 Servo Ready(/S-RDY) Output
Type
Type
Type
Type
Signal
Signal
Signal
Signal
Name
Name
Name
Name
Connector
Connector
Connector
Connector
Pin
Pin
Pin
Pin Number
Number
Number
Number
Setting
Setting
Setting
Setting
Meaning
Meaning
Meaning
Meaning
Output
/TGON
CN1-5,CN1-6
(
Factory
setting
)
ON(low level)
Servomotor is operating(Servomotor
speed is above the setting in Pn503).
OFF(high level)
Servomotor is not operating(Servomotor
speed is below the setting in Pn503).
This signal is output to indicate that the servomotor is currently operating above the setting in
parameter Pn503.
Pn503
Rotation Detection Speed TGON
Setting
Setting
Setting
Setting range
range
range
range
Setting
Setting
Setting
Setting unit
unit
unit
unit
Factory
Factory
Factory
Factory setting
setting
setting
setting
Setting
Setting
Setting
Setting validation
validation
validation
validation
0
~
3000
rpm
20
Immediately
Sets the range in which the rotation detection output signal (/TGON) is output in this parameter.
When the servomotor rotation speed is above the value set in the Pn503, it is judged that
servomotor rotation speed signal (/TGON) is output.
The rotation detection signal can also be checked on the panel operator.
Type
Type
Type
Type
Signal
Signal
Signal
Signal Name
Name
Name
Name
Connector
Connector
Connector
Connector Pin
Pin
Pin
Pin
Number
Number
Number
Number
Setting
Setting
Setting
Setting
Meaning
Meaning
Meaning
Meaning
Output
/S-RDY
CN1-9,CN1-10
(
factory setting
)
ON(low level)
Servo is ready.
OFF(high level)
Servo is not ready.
This signal indicates that the servodrive received the servo ON signal and completed all preparations.
It is output when there are no servo alarms and the main circuit power supply is turned ON.
Position
Torque
Speed