ENVIRONMENTS AND INSTALLATION
19
2.5. Installation Procedure
CAUTION
!
The robot system must be installed to avoid interference with buildings,
structures, utilities, other machines and equipment that may create a trapping
hazard or pinch points.
Vibration (or sympathetic vibration) may occur during operation as the rigidity of
worktable. If it does, please improve the rigidity of the worktable, or change the
settings of speed, acceleration and deceleration.
2.5.1. Standard-model
CAUTION
!
Install the Table Top Mounting Robot with two or more people. Be careful not to
get hands, fingers, or feet caught and/or have equipment damaged by a fall of
the Robot.
(1) Secure the base to the base table with four bolts.
Fig 2.8 Secure the base table (ER3&ER6)
CAUTION
!
Use bolts with specifications conforming to ISO898-1 Property Class: 10.9 or
12.9. The tightening torque is 32.0 N·m (326kgf·cm).