TRIO SCARA Robot Mechanical Unit Operator's Manual
Document Version: V1.8
© 2022 TRIO MOTION TECHNOLOGY
All right reserved.
44
5.1.2.
Inspection While the Power is ON (Robot is operating)
Inspection Point
Inspection Place
Daily
Monthly Quarterly
Biannual
Annual
Check motion range
Each joint
✓
Move the cables back and forth lightly
to check whether the cables are
disconnected.
External cables
(including cable
unit of the Robot)
✓
✓
Push each arm in MOTOR ON status
to check whether backlash exists.
Each arm
✓
Check whether unusual sound or
vibration occurs.
Whole
✓
✓
✓
✓
✓
Measure the accuracy repeatedly by
a gauge.
Whole
✓
Turn ON and OFF the brake release
switch and check the sound of the
electromagnetic brake. If there is no
sound, replace the brake.
Brake
✓
✓
✓
✓
✓