58
CV
Name
Description
Range Value
120 AUX 6 configuration
Configuration of output „AUX 6“
0 - 255
15
(LokPilot XL only)
Description
Value
continuous (dimmer)
Vol
blinking (Phase 1)
Vol + 16
blinking (Phase 2)
Vol + 32
Strobe light
Vol + 48
Double Strobe light
Vol + 64
Fire box
Vol + 80
Smoke generator
Vol + 96
Headlight bright/dim
Vol + 112
Marslight
Vol + 128
Gyrolight
Vol + 144
„Rule 17“ for head light
Vol + 160
„Rule 17“ for rear light
Vol + 176
Output „Pulse“ (time-restricted)
Vol + 192
Vol = bightness. Range 0 (dark) - 15 (maximum)
124 Auxiliary settings
Controls auxiliary settings of the LokSound decoder
6
Description
Value
Store direction (Motorola®)
1
Store function state
2
Store current speed setting
4
Start again with acceleration ramp
8
No emergency stop during direction switch for Motorola operation
16
No PWM in analog operation
64
No PWM for function outputs for analog operation (interconnection)
128
125 Voltage of engine Analog DC
(not for LokPilot Fx V3.0 and LokPilot Fx micro V3.0)
0-127
15
126 Maximum speed
(not for LokPilot Fx V3.0 and LokPilot Fx micro V3.0)
0-127
45
Analog DC
127 Voltage of engine Analog AC
(not for LokPilot micro V3.0, LokPilot micro V3.0 DCC, LokPilot Fx V3.0 & Fx micro) 0-127
15
128 Maximum speed
(not for LokPilot micro V3.0, LokPilot micro V3.0 DCC, LokPilot Fx V3.0 &
0-127
45
Analog AC
LokPilot Fx micro V3.0)
List of all supported CVs
Summary of Contents for LokPilot Fx micro V3.0