72
CV
Name
Description
Range
Value
124
Extended Configuration #2
Additional important settings for decoders.
-
0
Bit
Description
Value
0
Bi-directional bit: Enable driving direction when shifting
direction.
Disable driving direction.
1
0
1
Disable decoder lock with CV 15 / 16
Enable decoder lock with CV 15 / 16
0
2
3
Disable serial protocol for C-Sinus
Enable serial protocol for C-Sinus
0
8
4
Adaptive regulation frequency
Constant regulation frequency
0
16
125
Starting voltage Analog DC
(not for LokPilot Fx V4.0)
0-255
30
126
Maximum speed Analog DC
(not for LokPilot Fx V4.0)
0-255
130
127
Starting voltage AC
(not for LokPilot V4.0 DCC and LokPilot Fx V4.0)
0-255
50
128
Maximum speed Analog AC
(not for LokPilot V4.0 DCC and LokPilot Fx V4.0)
0-255
150
132
Grade Crossing Hold Time
Grade Crossing holding time. See chapter 12.3.3.
246
Automatic decoupling
Driving speed
Geschwindigkeit, mit der die Lok beim Entkuppeln fährt. Je größer der Wert,
desto schneller die Lok. Der Wert 0 schaltet die automatische Entkupplung ab.
Automatisches Entkuppeln nur aktiv, wenn der Funktionsausgang auf „Pulse“ oder
„Kuppler“ gestellt ist.
0 - 255
0
247
Decoupling - Removing time
This value multiplied with 0.016 defines the time the loco needs for moving away
from the train (automatic decoupling).
0 – 255
0
248
Decoupling - Pushing time
This value multiplied with 0.016 defines the time the loco needs for pushing against
the train (automatic decoupling).
0 – 255
0
253
Constant brake mode
Determines the constant brake mode. Only active, if CV254 > 0
0 – 255
0
Funktion
CV 253 = 0: Decoder stops linearly
CV 253 > 0: Decoder stops constantly linear
254
Constant braking distance
A value > 0 determines the way of brake distance it adheres to, independent from
speed.
0 – 255
0
List of all supported CVs (DCC decoders)
Summary of Contents for LokPilot Fx V4.0
Page 74: ...74 Notes ...