14
Configuration with LokProgrammer
6.3.1. Basic address
• Click on the „Decoder” icon on the left column. As a second step,
select the Address group from the centre column.
You can now set the base address of the SignalPilot. The basic
address is used for programming CVs on the main (POM), but
otherwise has no influence on switching the signals. These use
different addresses (resp. turnout numbers).
The SignalPilot always applies the methods as per the RCN-213
standard to address turnout numbers and turnout addresses. Ol-
der ROCO® command stations (e.g.: multiMouse) use a different
address calculation method. Here, the turnout numbers can devi-
ate by the value of „4”.
6.4. „Signals” register
No further relevant settings can be made in the „Decoder” regis-
ter. All settings for the SignalPilot and the connected signals are
made in the „Signals” register.
• Click on the “Signals” icon in the left column of the screen.
You will now see the main window, which is structured as follows:
a) Choice menu for predefined signal aspects, thematically grou-
ped.
b) Work area with SignalPilot and connected signals.
c) Detail area for setting options of the selected element.
d) Screenshot button for saving the detail area as an „electronic
wiring plan”.
The appearance of the detail area (box) on the right changes de-
pending on whether an item is selected, and if so, which item is
displayed the detail box.
b)
a)
c)
d)