background image

       

 

 

A be
is to
cert
grou

Th

This
3-ph
appr

  The

The 
3-ph
syst
is w
insta
syst

Whe
rem
1.14
that

For 

                       

est practice f

o secure the 

ified to meet

unding electr

ree-Phas

s AC module c

hase circuit. T

ropriate circu

e AC cable is

microinverte

hase AC syste

em. Typically
ired to phase

allation patte

em. 

Figure 1

ether the mo

ains at 238 W

4 amps nomin
t can be conn

three 2-pole

 

16 amps x

                       

for all solar m

module supp

t requiremen

rode system 

se Instal

can be instal
The microinv

uit. 

s a 4-wire ca

er is a single 

em. It is imp

y during insta
es B and C a

ern ensure th

1: Example of 

odule is insta

Watts AC. W

nal current. U

nected to an 

, single throw

x 1.25 (safet

                       

module instal

port rails and

nts for ground

using a dedi

lation 

led in either 

verter autom

ble: L1, L2, N

phase devic

portant to ba

allation, for e

nd a third m

hat the modu

wiring single-

lled on a 240

hen connect

Use this nom

AC branch c

w 20A break

ty margin) =

                       

llers, especia

d hardware u

ding systems

cated, suitab

a residential 
atically sense

Neutral, and 

ce that is wire

lance the nu

each module 

module on ph

ules are not c

-phase microi

0 VAC or 208

ting modules 

inal current t

circuit. 

kers: 

= 20 amps ma

                       

ally those in a

using ground

s. Connect th

bly sized, cop

240 Vac spli

es the voltag

Ground.  

ed across tw

umber of mod

wired to pha

ases A and C

causing imba

nverter into a

8 VAC circuit,

to a 208V c

to calculate t

ax module A

                       

w

areas with fr

ing hardware

he entire stru
pper conduct

t-phase circu

ge and provid

wo of the thre

dules wired t

ases A and B

C (see Figure
alance within

a 3-phase syst

, the module

ircuit, the mo

the maximum

AC branch cir

www.etsolar.c

requent light

e that has be

ucture to a 

tor.  

uit or in a 208
des current to

ee phases in 

to the 3-phas

B, another mo

e 1). This 

n the 3-phase

em 

e's power rat

odule produc

m number of 

cuit cable ra

com 

ning, 

een 

8 Vac 

o the 

se 

odule 

 

ing 

ces 

units 

ting 

Summary of Contents for ET-P660250AC

Page 1: ...AC Module Installation Guide Content for ET P660250AC...

Page 2: ...r The information contained in this manual is based on ET Solar Group s knowledge and experience but such information and suggestions do not constitute a warranty expressed or implied The methods of i...

Page 3: ...isconnecting Latching Cables 12 Module Preparation 13 Preparing the Modules 14 Preparing the Last Module in the String 15 Module Installation 16 Installing the Modules 16 Examples 19 Junction Box Top...

Page 4: ...l Code Part I CSA C22 1 for Canada This unit or system is provided with fixed trip limits and shall not be aggregated above 30 kW on a single Point of Common Connection See Utility Interaction on page...

Page 5: ...for use with AC modules The AC dedicated branch circuit wiring from the readily accessible disconnect to the AC module array must include an equipment grounding conductor EGC run in the same raceway o...

Page 6: ...he user is en ures he receiving on between t nt into an ou an experienc 4 no more than r a 208 V sys ranch circuit nteractive he underside een the modu ral microinve ect current D side The fol hock rv...

Page 7: ...www etsolar com 5 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment...

Page 8: ...by a photov businesses In dule which is a separate m ally lethal DC h the integrat DC voltage pr gether is a s ghboring mod n time ule for a list of i AC cable c d with a sola voltaic PV m ntegrating...

Page 9: ...rized and inspected factory each assembly must pass a ground continuity check to verify electrical continuity from the AC cable ground contact to the module frame The AC cable provides equipment groun...

Page 10: ...le lled on a 240 hen connect Use this nom AC branch c w 20A break ty margin 8 llers especia d hardware u ding systems cated suitab a residential atically sense Neutral and ce that is wire lance the nu...

Page 11: ...nce of each module The layout diagram uses the serial number of the microinverter to identify where each module is installed in the array Use the module layout template below to create a module layout...

Page 12: ...Table 1 Mod 10 dule Layout D Diagram w www etsolar c com...

Page 13: ...emale conne lignment gro orrectly Ensu ce to secure t 11 es ctor into the oves and ridg ure both end the connecto latch male c ges that ensu ds are fully se ors Ensure b w connector ure the conne eate...

Page 14: ...w thumbs firm r until the lat ching Ca tool to safel tool into the when the too mly push or pu tch snaps fre 12 ables ly release the e latch recess ol is fully seat ull the top of ee e latching co se...

Page 15: ...nagement to secure the end of the AC cable Before connecting the transition cable calculate the distance from the transition box to the module plus the distance under the module to reach the appropria...

Page 16: ...on e clip and atta n the S clip ee clip to the s he AC cable co cking the mod dule backshee 14 a junction or ons included systems In te specific in represented i cess cable off before insta ach the 90...

Page 17: ...T Use an appro Module g will require n unused AC This unused c opriate cable 15 in the St a slightly dif connector O connector mu clip and end tring fferent prepa One end or th ust be secure d cap as...

Page 18: ...resting on the rail and uneven contact between the frame and the rail can cause damage to the microinverter and the module The metal components of the AC module including frame and microinverter can...

Page 19: ...t to ble into the c nnecting mod res are prope n the OFF po 17 e junction or o the transitio connector of dules to tran erly landed a osition r transition bo on box acco the first mo sition cable and...

Page 20: ...g If the string will continue to another row then an extension cable is needed Plug the extension cable into the current module and place it in the general vicinity of where the next module will be in...

Page 21: ...ion B s this append f cables nece module as yo Box Top dix provide ex essary for eac ou would see p Right 19 xamples of a ch configura e it when ins array configu tion The gra stalled w rations you m...

Page 22: ...Jun nction B Box Top p Left 20 w www etsolar c com...

Page 23: ...Tw wo String gs Two rows ea 21 ach w www etsolar c com...

Page 24: ...Tw wo String gs Sing gle Rows 22 w www etsolar c com...

Page 25: ...Lan ndscape e Two S Strings 23 w www etsolar c com...

Page 26: ...ller no s in the diagr WN 2 ectly to the se e receptacle o as shown or y as part of Ba wiring metho ger due to tem sor recommen x with distribu tor equirements fo und wires nt grounding fo metallic pa...

Page 27: ...ation company e Depends on ut may be larg surge suppress 25 es Exterior ra dule Cables a s require cable m d installer no s in the diagr device that ca double pole br WN 2 ectly to the se as shown or...

Page 28: ...x with distribu ation contract und wires nt grounding fo metallic parts ans of equipm s recommende g to bond all m g PV module f und electrode es Exterior ra the AC modul onnect device s require conn...

Page 29: ...the module frame a able parallel to vailable in box ttaches to the module frame a able perpendic dge vailable in box overs the fem onnector at th rotect the AC able from dirt vailable in box overs the...

Page 30: ...e co nd and 100 mm n the other 0A exterior ra and Ground1 vailable in 5 a ach cable is sh able release to atch male cab ne end and 10 wires on the ot 0A exterior ra and Ground1 vailable in 5 a ach cab...

Page 31: ...on th 0A exterior ra and Ground1 vailable in 5 a Latch male int onnectors on b 0A exterior ra and Ground1 vailable in 5 a emale cable co nds 0A exterior ra and Ground1 vailable in 5 a www etsolar c o...

Page 32: ...le cable plug One disconnect able type kit with standa 9 conversion able receptacle atch male cabl ther end 1 conversion able connecto male cable plug One disconnect able type www etsolar c efficiency...

Page 33: ...rmal output frequency 60 Hz 60 Hz Maximum continuous output current ac 1 14 A5 0 992 A4 Maximum output power ac 238 W 238 W Utility interconnection voltage and frequency trip limits and trip times See...

Page 34: ...ection No Fans Protection Level IP 65 NEMA 6 6 This is the maximum number of microinverters that can be connected in parallel to a single dedicated branch circuit which is protected by a 2 pole circui...

Page 35: ...Tr ility Inter on adjustable m ominal voltage rip limit accurac raction maximum clearin equals 120V ph cy Voltage 2 ng times hase to neutral 2 5 based on 1 33 120V nominal f frequency 0 1 w 1 Hz www...