20
3.1.1 Constant Current Mode (CC)
In constant current mode, the DC E-load will sink a constant current, regardless of the
voltage of the source. See the figure below.
Figure 3.1 CC mode
In CC mode, the E-load provides two methods to set the constant current value.
1) In CC mode, use the numeric keys to input the current value, press the key
to
confirm the setup constant current value, and press the key
to load or unload the
source.
2) Press the key
to move the cursor position and press the key
to adjust the value
at the corresponding position.
ET System electronic GmbH