E Leimer GmbH
Postfach 10 15 40
D-86136 Augsburg
Phone (0821) 24 35-0
Telefax (0821) 24 35-6 66
Internet http://www.erhardt-leimer.com
E-mail info@erhardt-leimer.com
The electrical spare parts are dependent on the on-site control volta-
ge.
(only in conjunction with a switch panel)
Miniature fuse (5x30) 10 AM (24 V)
070646
Miniature fuse (5x30) 4 AM (120 V)
012043
Miniature fuse (5x30) 2 AM (230 V)
005353
((only in conjunction with a terminal box)
Miniature fuse (5x30) 6,3 AM
012044
Technical data
HP 0360
HP 0370
3-phase motor
see sticker motor rating
Operating pressure
20 bar
30 bar
Pressure on cylinder
when adjusted to maximum
14 bar
21 bar
Pump delivery
1,5 - 3 l/min
3 - 6 l/min
Fluid content
15 l
25 l
Fluid type
H-LP 32 DIN 51524
ISO VG 32 DIN 51519
Temperature rise
above ambient
35 °C
45 °C
Maximum operating
temperature
80 °C
Sound level
64 dB
Sensor air pressure
5 - 30 mbar
Weight with fluid
approx. 40 kg approx. 45 kg
Valve coil voltage
220-230 V, 50/60 HZ
110-120 V, 50/60 HZ
24 V =
2/2-way valve
31 VA / 15 W
4/3-way valve
80 VA / 30 W
Dimensions
see attached dimensioned
drawing
Subject to technical modifications without notice
9. Technical Data
8.2 Electrical components