ETA-ECM2063 

AC Power Distribution Sequencer

IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.

2.  Keep these instructions.

3.  Heed all warnings.

4.  Follow all instructions.

5.  Do not use this device near water.

6.  Clean only with dry cloth.

7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other device (including amplifiers)  
 

that produce heat. 

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the 
 

other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your  

 

safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they  
 

exit from the device.

11. Only use attachments/accessories specified by the manufacturer.

12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the device. When a cart is used,  
 

use caution when moving the cart/device combination to avoid injury from tip-over.  

13. Unplug this device during lightning storms or when unused for long periods of time. 

14. Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, such as  
 

power-supply cord or plug is damaged, liquid has been spilled, or objects have fallen into the device, the device has been exposed  

 

to rain or moisture, does not operate normally, or has been dropped. 

15. 

WARNING:

 To reduce the risk of fire or electric shock, this device should not be exposed to rain or moisture and objects filled with  

 

liquids, such as a vase, should not be placed on this device. 

16. To completely disconnect this equipment from the mains, disconnect the power supply cord plug from the receptacle. 

17. The mains plug of the power supply cord shall remain readily operable. 

The lightning flash with arrowhead symbol within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage “ within the 
product’s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons. 

The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the 
literature accompanying the product.  

Summary of Contents for ETA-ECM2063

Page 1: ...s are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECM2063 AC Power Distribution Sequencer ETA ECM2063 AC Power Distributio...

Page 2: ...lephone 800 321 6699 Fax 800 996 3821 ETA ECM2063 AC Power Distribution Sequencer TABLE OF CONTENTS Important Safety Instructions 3 Introduction 5 Key Features 5 Applications 5 Raceway AC Inlet Knocko...

Page 3: ...d tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip over 13 Unplug this dev...

Page 4: ...not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure that the saf...

Page 5: ...ETA ECM2063 or from several feet away by using an ETA Systems sequence controller or via a switch The ETA ECM2063 was designed to be compact measuring only 37 high 3 5 wide and 2 75 deep The ETA ECM20...

Page 6: ...pporting standard USA electrical fittings of 1 2 and 3 4 The figure below is an illustration of one end of the raceway RACEWAY MOUNTING RAILS The ETA ECM2063 raceway has breakaway rail mounting tabs t...

Page 7: ...f the channel control port pins together An activation sequence can be triggered using an ETA SEQ6 or ETA ECS6RM sequence controller or by using another external device such as a hard contact switch t...

Page 8: ...AC mains Accessing the Internal Wiring 1 Locate the Control Input Panel 2 Remove the four screws See diagram below 3 Remove the Control Input Panel Note A ribbon cable is attached Carefully lay panel...

Page 9: ...ains inlet on the bottom of the raceway that allows for the easiest connection to the AC Mains line based on the layout of the installation 3 Strip the wires 3 8 4 Locate J23 L3 on the PCB Insert the...

Page 10: ...te J23 L3 on the PCB Remove the wire jumpers from P2 N and P3 H Remove wire from push on spade lug discard 2 wires 5 L1 L2 wiring Locate J24 L2 on the PCB Insert the 20A AC Mains wires into J24 L2 and...

Page 11: ...wires 3 8 4 Locate J25 L1 on the PCB Remove the wire jumpers from P2 N and P3 H Remove wire from push on spade lug discard 2 wires 5 L1 wiring Locate J25 L1 on the PCB Insert the 20A AC Mains wires i...

Page 12: ...P2 N and P3 H Remove wire from push on spade lug discard 2 wires 6 L1 wiring Locate J25 L1 on the PCB Insert the 20A AC Mains wires into J25 L1 and secure by tightening the screws firmly Ground Green...

Page 13: ...Outlets 12 NEMA 5 20 Switched Connectors Qty 6 2 Position Phoenix Euro Block Style 3 5mm Spacing Remote Trigger Hard Switch Contact Closure Indicators Incoming AC Red Active Green AC Mains Interconnec...

Page 14: ...14 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECM2063 AC Power Distribution Sequencer NOTES...

Page 15: ...15 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECM2063 AC Power Distribution Sequencer NOTES...

Page 16: ...below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included wi...

Reviews: