ETA-PD8 

Power Conditioner & Distribution Unit

AC POWER CORD RETAINER SYSTEM

4.  Wrap the zip tie around the power cord as shown in Figure 4.

5.  Feed the end of the zip tie through the retainer and pull tightly  
 

to secure. 

Note:

 Some adjustment of the retainer may be   

 

needed in order to properly align it as shown in Figure 6.

6.  Cut the excess zip tie off as shown in Figure 7.

Your ETA Systems product comes with an AC Mains Power Cord Retainer System. This system prevents the power 
cord from being removed without the use of a screwdriver. Follow these steps for installation.

Note: 

Installation of this product must be done by a certified electrician for a permanently connected apparatus provided 

neither with an all-pole mains switch nor an all-pole circuit breaker. A readily accessible disconnect device shall be 
incorporated in the building installation power wiring. The installation shall be carried out in accordance with all applicable 
installation rules in accordance with all applicable federal, state, and local laws, regulations, safety codes and ordinances. 

1.  Locate the 6/32 screw, retainer clip, and zip tie. 

2.  Locate the AC wall outlet that will be used to power the  
 

Atlas Power product. Remove the center screw securing the  

 

cover plate  to the AC outlet.

3.  Place the screw through the retainer clip and insert into the  
 

cover plate making sure to securely tighten. Inset the zip tie  

 

through the retainer clip slots as shown in Figure 3.

Figure 1

Figure 5

Figure 6

Figure 7

Figure 4

Figure 2

Figure 3

Summary of Contents for ETA-PD8

Page 1: ...ifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8 Power Conditioner Distribution Unit ETA PD8 Power Conditioner Distribution Unit ...

Page 2: ...xas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8 Power Conditioner Distribution Unit TABLE OF CONTENTS Important Safety Instructions 3 Introduction 5 Key Features 5 Applications 5 Front Panel 6 Rear Panel 6 Installation 6 AC Power Cord Retainer System 7 Specifications 8 Warranty 12 ...

Page 3: ...over 13 This product is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 14 Unplug this device during lightning ...

Page 4: ...doing so may result in fire or electrical shock Ensure that the safety ground terminal is connected to a proper ground Never connect the ground to a gas pipe as a catastrophic disaster may result Be sure the installation of the product is stable avoid slanted surfaces as the product may fall and cause injury or property damage Installation of this product must be done by a certified electrician fo...

Page 5: ...peaks of 3000A These spikes are very fast and usually only last for a very short period of time The ETA PD8 s circuitry is very fast and can suppress unwanted energy within a nanosecond response and sustain the suppression up to 2 milliseconds thus ensuring virtually trouble free protection The ETA PD8 offers power management control noise filtering and spike surge protection making it the most co...

Page 6: ...hen in the On position REAR PANEL FEATURES 1 AC Mains Input Connect the 9 3m power cord to a 15A 120VAC outlet to provide power to the ETA PD8 2 AC Switched Power Outlets These six outlets are Live when the front panel power switch is activated 3 AC Unswitched Power Outlets These two outlets are always Live when the ETA PD8 is plugged into a 120VAC source Installation Before installing we strongly...

Page 7: ...e Installation of this product must be done by a certified electrician for a permanently connected apparatus provided neither with an all pole mains switch nor an all pole circuit breaker A readily accessible disconnect device shall be incorporated in the building installation power wiring The installation shall be carried out in accordance with all applicable installation rules in accordance with...

Page 8: ...Cord 9 3 Meters 14 gauge Technical Data Current Rating 15 amps Power Consumption 6 watts Operating Voltage 102 132VAC Min Spike Clamping Voltage 460 VRMS 3 000A Max Spike Clamping Voltage 6kV Max Spike Clamping Resp Time 1 nanosecond Spike Clamping Voltage 100A 1250Vp for 20μs Maximum Surge Current 6 500A Energy Rating 2ms 200 Joules Noise Attenuation EMI RFI 10dB 10 kHz 40dB 100 kHz 100dB 10 MHz ...

Page 9: ... 9 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 NOTES ETA PD8 Power Conditioner Distribution Unit ...

Page 10: ... 10 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 NOTES ETA PD8 Power Conditioner Distribution Unit ...

Page 11: ... 11 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 NOTES ETA PD8 Power Conditioner Distribution Unit ...

Page 12: ...tems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written request for an estimate of repair costs before any non warranty work is performed In the event of replacement or upon completion of repairs return shipment will be made with the transportation charges col...

Reviews: