background image

 

– 7 – 

ETAsys.com

Specifications are subject to change without notice.

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800-321-6699 • Fax: 800-996-3821

ETA-PD8A 

AC Power Conditioner & Distribution Unit

FRONT PANEL FEATURES

1. Unswitched AC Outlet

The 120VAC outlet is always live when the ETA-PD8A power cord is plugged into an AC mains power source. 

Note:

 The AC mains 

power switch does not affect the Unswitched AC Outlet but it is protected with surge protection circuitry.

2. Power Switch & Cover

  To turn the ETA-PD8A On or Off, press the switch to the On or Off position. When in the On position and AC voltage is present the 
power LED will illuminate. The ETA-PD8A incorporates a power switch cover to prevent accidental pressing of the power switch.

3. Switched Outlets Active Indicator 

This LED will illuminate Blue when the power switch is in the On position.

4. Surge Protect Indicator  

The Surge Protect LED is illuminated under normal operating conditions showing that the surge protection circuit is functioning 
correctly and the connected equipment is protected from voltage transients. Although the clamping suppression circuit virtually assures 
protection from most transient voltage spikes and surges, nature has a way of occasionally creating electrical forces that are beyond 
the capabilities of any device to absorb without some degree of damage. In the rare instance that this occurs and the circuit has been 
damaged, the Red “Surge Protect” LED indicator will turn off. The ETA-PD8A will shut off permanently until the unit is repaired. Be 
advised that activation of this fault condition and the associated repair is not covered under warranty. 

Note:

 If the Surge Protect LED is 

not illuminated while the unit is powered on, it is important to have all equipment that was connected to that AC Mains Line inspected 
for proper operation.

5. Ground Status Indicator

This LED will illuminate Green when the ETA-PD8A has Earth ground connection on the Earth ground pin of the AC Mains power cord. 

Note:

 If there is no Earth ground connection the LED will not illuminate and the AC wall outlet must be repaired by a qualified electrician 

before continuing.

1

2

3

4

5

Summary of Contents for ETA-PD8A

Page 1: ...tions are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8A AC Power Conditioner Distribution Unit ETA PD8A AC Power Condit...

Page 2: ...elephone 800 321 6699 Fax 800 996 3821 ETA PD8A AC Power Conditioner Distribution Unit TABLE OF CONTENTS Important Safety Instructions 3 Introduction 5 Key Features and Applications 6 Front Panel Desc...

Page 3: ...y with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip ove...

Page 4: ...r cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure th...

Page 5: ...ference The ETA PD8A is unique in that the integrator can select the power cord length that is required for the installation A removable 12 IEC power cord with a retainer bracket is supplied with the...

Page 6: ...rcuit Breaker Protection 15A Spike Suppression up to 6000V AC Fault Indicator Ground Status Indicator Removable IEC Power Cord with a Retainer Bracket APPLICATIONS The ETA PD8A was designed to be flex...

Page 7: ...rotection circuit is functioning correctly and the connected equipment is protected from voltage transients Although the clamping suppression circuit virtually assures protection from most transient v...

Page 8: ...iner bracket installation 3 AC Mains Power Breaker The 15A rated breaker will open if the combined draw of all AC outlets exceeds 15A Note The breaker is designed to exceed its rating for a short peri...

Page 9: ...ake sure the 15A outlet is properly inspected by a certified electrician prior to connecting the ETA PD8A Make sure to inspect the equipment that will be connected to the ETA PD8A to ensure it does no...

Page 10: ...ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8A AC Power Conditioner Distribution Unit NOT...

Page 11: ...ket 15A 1800W Circuit Breaker 15A Resettable Technical Data Max AC Mains Current 15A AC Mains Breaker Operating Voltage 102VAC 132VAC Power Consumption 6 Watts Min Spike Clamping Voltage 460 VRMS 3 00...

Page 12: ...forth below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is includ...

Reviews: