8489 Non-Paired - Audio, Control and Instrumentation Cable
For more information please
call
1-800-Belden1
See Put-ups and Colors
Related Documents : No. 1.pdf
Description:
18 AWG stranded (19x30) tinned copper conductors, conductors cabled, PVC insulation, PVC jacket.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Conductors
4
Total Number of Conductors
4
AWG
18
Stranding
19x30
Conductor Material
TC - Tinned Copper
INSULATION:
Insulation Material
PVC - Polyvinyl Chloride
Nom. Insulation Wall Thickness
.017 in.
OVERALL CABLING:
Overall Cabling Lay Length
3 in.
Overall Cabling Twists/ft.
4
Overall Cabling Color Code Chart :
Number
Color
1
Black
2
White
Number
Color
3
Red
4
Green
OUTER SHIELD:
Outer Shield Material
Unshielded
OUTER JACKET:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Nominal Wall Thickness
.032 in.
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter
.257 in.
MECHANICAL CHARACTERISTICS:
Page 1 of 3