GB - 56
GB
Repositioning the door
•
It is not possible to change the opening direction of your refrigerator door, if the door handle
on your refrigerator is installed from the front surface of the door.
•
It is possible to change the opening direction of the door on models without any handles.
•
If the door opening direction of your refrigerator should be changed, you should contact the
nearest Authorised Service Agent to have the opening direction changed. This change is
payable by the consumer.
PART- 6.: EFORE CALLING THE SERVICE
Check Warnings;
Your fridge warns you if the temperatures for cooler and freezer are in improper levels or when
a problem occurs in the appliance. Warning codes are displayed in the freezer and cooler indicators.
ERROR
TYPE
MEANING
WHY
WHAT TO DO
SR
Failure Warning
There is/are some
part(s) Out of order
or there is a failure in
cooling process
Call a service agent for assi
-
stance as soon as possible.
LF
Freezer comp. Not
Cold enough
This caution will be
seen especially after
long term power
failure
1. Use food in short time period.
Do not freeze foods that has
thawed.
2. Set the freezer temperature
to colder values or set
the super freeze until the
compartment gets to normal
temperature.
3. Do not put fresh food in the
appliance until the fault has
cleared.
LC
„Refrigerator comp.
Not Cold enough“
Ideal temperature for
Ref. Compartment is
+4 oC. If you see this
warning your foods
are at risk of spoiling
1. Set the refrigerator
temperature to colder values
or set the super cooling mode
until the compartment reaches
normal temperature.
2. Open the door as little as
possible until the fault clears.
LF a LC
Not cold enough
Warning
This is a combination
of LF and LC Error
type
You will see this failure when
first starting the appliance. It will
clear after the compartments
reach normal temperature.
HC
Refrigerator comp. too
Cold
The food starts to
freeze because the
temperature is too
cold
1. Check if the “Super cooling
mode” is not on
2. Increase the refrigerator tem
-
perature values
LOPO
Low voltage Warning
This is seen when the
power supply gets
lower than 170 V.
This not a failure. This prevents
any damage to the compressor.
This warning will clear after the
voltage reaches the required
level.