EN - 46
EN
III. INSTALLATION
Space Requirement
•
Keep enough space of door open.
•
Keep at least 50mm gap at two sides.
A
559 mm
B
628 mm
C
1920 mm
D
min=50
mm
E
min=50
mm
F
min=50
mm
G
977 mm
H
1122 mm
I
130 °
Leveling the unit
915
mm
1075
mm
To do this adjust the two leveling feet at front of the unit.
If the unit is not level, the doors and magnetic seal
alignments will not be covered properly.
Note: Above pictures are for reference only.
Positioning
Install this appliance at a location where the ambient temperature corresponds to the
climate class indicated on the rating plate of the appliance. For refrigerating appliances
with climate class:
- extended temperate: ‘this refrigerating appliance is intended to be used at ambient
temperatures ranging from 10 °C to 32 °C (SN)
- temperate: ‘this refrigerating appliance is intended to be used at ambient
temperatures ranging from 16 °C to 32 °C (N)
- subtropical: ‘this refrigerating appliance is intended to be used at ambient
temperatures ranging from 16 °C to 38 °C (ST)
- tropical: ‘this refrigerating appliance is intended to be used at ambient
temperatures ranging from 16 °C to 43 °C (T)
Location
The appliance should be installed well away from sources of heat such as radiators,
boilers, direct sunlight etc. Ensure that air can circulate freely around the back of the
Summary of Contents for 253090040E
Page 96: ......