Connect the precipitator with the boiler
Installation
horizontal alignment is important, because equal
clearance of the electrode to the inner walls is required
on all sides.
Fig. 5-2: Check alignment
Fig. 5-3: Electrode
The precipitator can also be placed in another
location in exceptional cases. Contact us about
optimising the installation of the precipitator in this
regard. The piping between the boiler and precipitator
as well as the flue gas recirculation piping must be set
up separately.
If the boiler is placed on sound insulation mats,
the precipitator must also be placed on
sound insulation mats.
Install the draught fan and flue gas connection
Remove the panel from the top of the precipitator.
Evenly mount the draught fan with hexagonal screws
onto the precipitator.
A longer connection line for the draught fan
already protrudes from the precipitator. Plug it
into the draught fan and guide the other end over the
cable duct to the boiler. Remove the existing line
located there and clamp in the longer connection line
in its place.