Cleaning and maintenance
Cleaning (customer)
25
Cleaning of the flushing air opening
Use an ash vacuum to vacuum out the openings for the
flushing air of the electrodes at the insulators.
Fig. 2-50: Flushing air opening on the isolator
Do not clean the openings with compressed air,
as this will stir up ash which may reach the control
system of the precipitator and damage it.
Cleaning and checking the electrode holder
Clean the electrode holder with a soft cloth.
Fig. 2-51: Electrode holder
Afterwards carry out a status check of all
electrode holders. The best way to do this is to
stroke your hand over the electrode holder and, above
all, check the area near the flushing air opening. If
cracks or small holes can be "felt", there is damage. In
this case, contact ETA Customer Support.
Check the alignment of the electrodes
The electrodes must be in the centre of the precipitator,
so that the flue gas can be optimally cleaned.
Therefore, check the gaps from the electrodes to the
inner walls.
Fig. 2-52: Electrodes
If the gap is uneven, check the electrode. They
may have been bent during cleaning.
Re-attach the perforated plates.