Changing the fuel
17
Adaptations for
HACK 63-90 kW
Fuel
Pellets
Wood chips
Carpentry material
Miscanthus
a
a. Reduced max. output: 65 kW
Water content
< 15%
< 15%
15 - 25%
25 - 35%
< 15%
< 20%
Ash/dust content
low
high
low
high
low
high
low
high
low
high
low
high
Software parameters [Fuel]
[Pellets]
[Woodchips]
[Woodchips]
[Miscanthus]
Firebed level sensor
Position
2
3
5
3
5
De-ashing interval (boiler with buffer storage tank
)
Software parameters
[De-ash after min.]
80 kg
28 kg
35 kg
9 kg
35 kg
9 kg
35 kg
9 kg
17 kg
9 kg
2 kg
2 kg
[De-ash after max.]
120 kg
90 kg
65 kg
33 kg
65 kg
33 kg
65 kg
33 kg
65 kg
33 kg
15 kg
12 kg
De-ashing interval (boiler without buffer storage tank
)
Software parameters
[De-ash after min.]
80 kg
57 kg
35 kg
18 kg
35 kg
18 kg
35 kg
28 kg
35 kg
18 kg
5 kg
5 kg
[De-ash after max.]
120 kg
90 kg
65 kg
33 kg
65 kg
33 kg
65 kg
33 kg
65 kg
33 kg
15 kg
12 kg
Boiler with flue gas recirculation installed
Software parameters [Flue gas recirculation]
[Yes]
[Yes]
[Yes]
(recom-
mended)
[Yes]
[No]
[Yes]
[Yes]
Flue gas recirculation status
Open
Open
Open
(recom-
mended)
Open
Closed
Open
Open
Boiler without flue gas recirculation
Software parameters [Flue gas recirculation]
[No]
Summary of Contents for HACK 20
Page 1: ...2017 01 30 EN 0000000294 V 003 2 38 0 3005 3106 93526 001 Wood chip boiler 20 90 kW Operation ...
Page 15: ...Changing the fuel Settings 15 4 2 Settings ...
Page 35: ...ETAtouch controller Boiler function block HACK 35 ...
Page 45: ...ETAtouch controller Buffer function block 45 ...
Page 49: ...ETAtouch controller Hot water tank function block 49 ...
Page 53: ...ETAtouch controller Fresh water module function block 53 ...
Page 67: ...ETAtouch controller Solar function block 67 ...
Page 73: ...ETAtouch controller Heating pipeline function block 73 ...
Page 92: ...www eta co at www eta co at downloads DOWNLOAD ...