20
www.eta.co.at
Start-up
Close fuel chamber door, open ignition door
Close the fuel chamber door and then open the ignition
door.
If the boiler will not be started up yet, close both
doors and, in the boiler overview, switch off the
boiler using the
switch.
Ignite fire with cardboard and newspaper
Place crumpled paper or a few pieces of cardboard in
front of the first layer of wood and ignite it. The draught
fan sucks the flame over the tightly stacked logs,
causing them to ignite more quickly. For heavy, smooth
hardwood, larger pieces of kindling may be needed for
ignition.
CAUTION!
Never use petrol, turpentine or similar materials as an
"ignition aid": risk of explosion!
The ignition door should be kept open after
ignition to monitor the progress of the fire. It
should only be closed once the boiler's exhaust
temperature has reached 100°C.
How long it takes the fire to start depends on the type
of wood used; rough spruce may need only 2 minutes,
smooth beech may require 5 minutes until the exhaust
gas temperature reaches 100°C.
At 100°C exhaust temperature, close ignition door
and insulating door
Once a few logs are burning well and the exhaust
temperature is over 100°C, close the ignition door and
the insulating door.
Fig. 8-1: Close ignition door
Summary of Contents for TWIN 20 kW
Page 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Page 39: ...ETAtouch controller TWIN function block 39 ...
Page 49: ...ETAtouch controller Buffer function block 49 ...
Page 53: ...ETAtouch controller Hot water tank function block 53 ...
Page 57: ...ETAtouch controller Fresh water module function block 57 ...
Page 81: ......
Page 82: ...www eta co at ...
Page 83: ......
Page 84: ...www eta co at ...