ETAtouch controller
Getting to know the control system
23
Several views are available for each function block. To
switch between these, tap on the
symbol at
the top left. The selection of views appears.
Fig. 9-2: Selection of views
1
User interface
2
Text menu
3
Inputs and outputs menu
4
Messages menu
In the user interface, you can set the most
important and common settings. For example,
adjustment of the charging times, heating
times, room temperatures and operating modes are
contained in this list. Details can be found in chapter
9.1.1 "User interface"
.
The parameters of a function block are
displayed in the text menu and can be
adjusted,if necessary, see chapter
9.1.2 "Text
menu"
.
The terminal assignment of individual
components, such as temperature sensors,
pumps and mixers, are visible within the input
and output menu, where they can be changed if
required. Also, for example, pumps and mixers can be
started in manual mode. This menu is intended for
specialists only. Details can be found in chapter
9.1.5
"Inputs and outputs"
.
Any hints, errors or faults are displayed in the
messages menu, see chapter
9.1.4
"Messages"
.
9.1.1
User interface
The user interface
The user interface is always displayed by default. If
you are in a different view, switch to the user view by
tapping the
symbol (upper left) and then
selecting .
In the user interface, you can set the most important
and common settings. The display is dependent on the
selected function block. The illustrated example shows
the user interface of a heating circuit with a room
sensor.
Fig. 9-3: Heating circuit user interface
1
Operating condition and information
2
Producer for the heating circuit.
Currently, the buffer provides a flow temperature of
65 °C to the heating circuit.
3
On/Off switch for the heating circuit
= switched on
= switched off
4
Increase or decrease the room temperature
5
Function block settings.
In this menu, the settings and functions most
commonly used can be stored. For the heating
circuit, for example, the heating times and the
heating curve are adjusted here.
6
Graphic display of the heating times and room tem-
peratures settings
7
Different operating modes of the heating circuit
Summary of Contents for TWIN 20 kW
Page 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Page 39: ...ETAtouch controller TWIN function block 39 ...
Page 49: ...ETAtouch controller Buffer function block 49 ...
Page 53: ...ETAtouch controller Hot water tank function block 53 ...
Page 57: ...ETAtouch controller Fresh water module function block 57 ...
Page 81: ......
Page 82: ...www eta co at ...
Page 83: ......
Page 84: ...www eta co at ...