ETAtouch controller
[TWIN] function block
37
temperature for measurement purposes. By pressing
the [Start now]
button, the boiler will immediately
begin preparations for a subsequent measurement.
Fig. 9-36: Settings window for emission measurement
In addition, the locking time of the boiler can be
adjusted in the settings window (
[Lock duration]
button). This relates to the set time of the measure-
ment. During this period no heating operation will be
started, so that the heating system has time to cool
down.
Example: If a time of 17:00 is set for the emission
measurement and at [Lock duration] 8 h, heating will
end at 09:00 .
The [Deactivate measurement]
button ends the
emission measurement and switches the boiler back to
normal mode.
Settings menu
In the settings menu (
[Settings] button in the
overview), the following functions and parameters can
also be set:
[Fill-up time] button
This sets the daily time for complete refilling of
the boiler pellet bin if pellets have been used.
This prevents refilling during the night. This
time applies for every day of the week.
[Hopper Fill] button
This fills the reservoir on the boiler immediately,
independent of the suction time settings.
9.3.2
Text menu - Adjustable parameters
Adjustable parameters
Detailed descriptions of the parameters are provided
below.
9.3.2.1
Start lag
Explanation of [Start lag]
This parameter is used to set the length of the delay in
operation of the pellet burner after the buffer has
demanded heat.
If there is still a demand from the buffer after this
period, then the pellet burner will begin operation.
The parameter can be found under:
9.3.2.2
Setting the idle time for boiler de-
ashing
Explanation of [Duration idle time]
The [Duration idle time] parameter is used to select the
duration of the idle time for the boiler's entire de-ashing
system.
The start time for the idle time is set with the [Start idle
time] parameter.
The idle time should be kept as short as possible.
If noise is not expected to be a nuisance, you
should reduce the value to 0 hours.
The parameters can be found under:
Boiler
Settings
Start lag
Ash removal
Start idle time
Duration idle time
De-ash after min.
De-ash after max.
Empty ash box after
Boiler
Settings
Start lag
Boiler
Ash removal
Start idle time
Duration idle time
Summary of Contents for TWIN 20 kW
Page 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Page 39: ...ETAtouch controller TWIN function block 39 ...
Page 49: ...ETAtouch controller Buffer function block 49 ...
Page 53: ...ETAtouch controller Hot water tank function block 53 ...
Page 57: ...ETAtouch controller Fresh water module function block 57 ...
Page 81: ......
Page 82: ...www eta co at ...
Page 83: ......
Page 84: ...www eta co at ...