54
www.eta.co.at
[Fresh water module] function block
ETAtouch controller
9.6
[Fresh water module] function
block
Fresh water module overview screen
1
Operating condition and information.
A description of the operating conditions can be
found in the integrated Help menu by pressing the
button.
2
Producer for the fresh water module.
Currently, the fresh water module is charged by the
buffer at a flow temperature of 58 °C.
3
Primary side return temperature
4
Circulation pump (only displayed if it has been
installed and is in operation)
5
Hot water temperature (the tap is displayed only
when hot water is currently being drawn)
6
[Settings] button.
In this menu, the time window can be set, for
example.
Function of the fresh water module
The desired hot water temperature is set with the po-
tentiometer on the fresh water module. If [Target value
can be set with rotary knob] has been disabled in the
configuration, different time windows and hot water
temperatures can be set. See chapter
9.6.1 "Setting
the hot water charging times"
.
Inside these time windows, the upper part of the buffer
is maintained at no lower than the configured hot water
temperature. Outside the set time windows, the hot
water is maintained at the lowest set temperature of
the time windows, provided that the accumulator tank
is sufficiently hot.
If a circulation pump is installed for the hot water,
it will be put into operation as "self-learning" by
default. This means that the hot water taps of the last
2 weeks are stored. The operating times of the current
day will be calculated from this and the circulation
pump is started accordingly.
When this function is switched off, the operating times
for the circulation pump can be set manually. This is
achieved by opening the settings (
button) and
pressing the
[Circulation times Daily plan] button.
After commissioning, no more data is available
for the "self-learning" circulation. That is why an
operating period of about 4 weeks is required in the
beginning, so that the control system can save
sufficient data.
Summary of Contents for TWIN 20 kW
Page 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Page 39: ...ETAtouch controller TWIN function block 39 ...
Page 49: ...ETAtouch controller Buffer function block 49 ...
Page 53: ...ETAtouch controller Hot water tank function block 53 ...
Page 57: ...ETAtouch controller Fresh water module function block 57 ...
Page 81: ......
Page 82: ...www eta co at ...
Page 83: ......
Page 84: ...www eta co at ...