[Heating circuit] function block
ETAtouch controller
9.7
[Heating circuit] function block
Overview of the heating circuit when a room
sensor is installed
Fig. 9-44: Heating circuit with room sensor
1
Operating condition and information.
A description of the operating conditions can be
found in the integrated Help menu by pressing the
button.
2
Producer for the heating circuit
3
On/Off switch for the heating circuit
= switched on
= switched off
4
Increase or decrease the room temperature
5
[Settings] button.
In this menu, the heating times and the heating
curve can be adjusted, for example.
6
Graphic display of the heating times and room tem-
peratures settings
7
Operating mode [Timer]
8
Operating mode [Set-back]
9
Operating mode [Heating]
Overview of the heating circuit without a room
sensor
In the overview, a temperature slider appears, rather
than the measured room temperature.
Fig. 9-45: Heating circuit without room sensor
1
Graphic display of the heating times settings
2
Temperature slider
Mode of operation
If the heating circuit is turned on (
), heat is
supplied on the basis of the time windows set. The
temperature is controlled with the heating curve (see
chapter
9.7.3 "The heating curve"
), the optional room
sensor and the time window settings (see chapter
9.7.2 "Setting the heating time slots"
).
During a time window, the heating circuit is in heating
mode. If a room sensor is installed, this regulates the
heating circuit so that the set room temperature is
achieved. If a room sensor is not installed, the heating
circuit is controlled with the heating curve for the
heating mode. Accurate temperature control is
therefore difficult.
Outside the set time slots, the heating circuit is in
reduced operation mode. This means that the room
sensor only regulates to the set reduced room
temperature [Set-back temperature outside the time
window]. Without a room sensor, the heating circuit is
controlled with the heating curve for the reduced
operation mode.
Switching between heating and reduced operation
takes place automatically when the
button is used
in the user interface to select the [Timer] operating
mode.
The operating modes are also manually adjustable.
Heating mode is activated with the
button, and
reduced operation mode with the
button. See
chapter
9.7.1 "Operating elements"
.
Summary of Contents for TWIN 20 kW
Page 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Page 39: ...ETAtouch controller TWIN function block 39 ...
Page 49: ...ETAtouch controller Buffer function block 49 ...
Page 53: ...ETAtouch controller Hot water tank function block 53 ...
Page 57: ...ETAtouch controller Fresh water module function block 57 ...
Page 81: ......
Page 82: ...www eta co at ...
Page 83: ......
Page 84: ...www eta co at ...