[Heating circuit] function block
ETAtouch controller
9.7.3.2
Setting the heating limits
Specifying the heating limits for the heating circuit
For each heating circuit, separate heating limits are
adjustable for heating mode (within the set heating
times) and reduced operation mode (outside the set
heating times).
If the current outside temperature exceeds the
configured heating temperature (for example 18 °C),
the heating circuit is switched off. The same applies to
reduced-temperature mode as soon as the outdoor
temperature exceeds the set heating limit.
If the outside temperature falls below the set
heating limit (for example: 18 °C), a hysteresis of
2 °C will be observed in order to avoid cycling the
heating circuit. Accordingly, the heating circuit will
switch on only once the outside temperature falls
below 16 °C (=18 °C - 2 °C).
The heating limits are adjusted through the settings of
the heating circuit (
button) in the heating curve
menu (
button).
Setting heating limits for heating mode
1. Change the selector switch to the heating mode
position (
).
Use the arrow keys to reduce parameter [Heating
threshold], so that the heating circuit in heating
mode switches off at a lower outside temperature,
or increase the value.
Fig. 9-55: Heating threshold for heating mode
Setting heating limits for the reduced operation
mode
1. Change the selector switch to the reduced
operation mode position (
).
Use the arrow keys to reduce parameter [Heating
threshold], so that the heating circuit in reduced
operation mode switches off at a lower outside
temperature, or increase the value.
At settings below 0 °C, there is a risk of
freezing.
Fig. 9-56: Heating limit for reduced-temperature mode
Summary of Contents for TWIN 20 kW
Page 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Page 39: ...ETAtouch controller TWIN function block 39 ...
Page 49: ...ETAtouch controller Buffer function block 49 ...
Page 53: ...ETAtouch controller Hot water tank function block 53 ...
Page 57: ...ETAtouch controller Fresh water module function block 57 ...
Page 81: ......
Page 82: ...www eta co at ...
Page 83: ......
Page 84: ...www eta co at ...