Regular cleaning
73
10 Regular cleaning
Stop heating, perform ember burnout
During the final heating operation with the log boiler,
press the [Ember burnout]
button in the boiler
overview (the button will then be shown in yellow
).
Ember retention is then deactivated and the log boiler
performs a complete ember burnout (duration approx.
1 hour). burning most of the charcoal in the fuel
chamber.
Also deactivate the pellet burner with the On/Off switch
in the pellet burner overview.
Begin maintenance only after the log boiler and
the pellet burner have cooled sufficiently.
Check heating system's water pressure
In buildings with up to three storeys, the optimum
water pressure in a cold heating system is
between 1 and 2 bar.
For a warm heating system, the optimum water
pressure is between 1.5 and 2.5 bar.
If the water pressure is too low, fill the cold heating
system to approx. 2 bar. Do not fill to a higher
pressure, as water expands with increasing
temperature and the water pressure also rises when
the boiler is heating. The safety valve triggers at
approx. 2.8 bar.
De-ash boiler
Use the poker to rake the ash out of the combustion
chamber and the ash collection duct into the ash pan.
The rear end of the ash collection duct must also be
cleared out so that there is no ash in front of the
lambda probe head.
The draught fan runs during de-ashing. So remove the
ash from the boiler slowly and gently to avoid stirring it
up too much and having it blown out through the flue.
Fig. 10-1: Removing ash from the combustion chamber
Fig. 10-2: Removing ash from the ash collection duct
The ash in the fuel chamber is needed as
insulation for ember retention. So approximately
3 cm of ash should be left in the fuel chamber. Scrape
the remaining ash from the fuel chamber into the
combustion chamber. Some pieces of charcoal will
drop into the combustion chamber during this process;
these are best left there. The charcoal will burn during
the next combustion cycle and the ash will protect the
bottom of the combustion chamber against premature
wear.
Fig. 10-3: Scraping extra ash and charcoal into the
combustion chamber
If there are still embers in the ash, leave the ash
in a closed, non-flammable container for at least
2 days. Only put it in the rubbish bin when it is certain
that there are no more embers present.
Do not slide the ash pan into the combustion
chamber. Although that is possible with 40 - 60
kW boilers, the ash pan is not intended for this purpose
and would be destroyed by the high temperatures
there.
Summary of Contents for TWIN 20 kW
Page 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Page 39: ...ETAtouch controller TWIN function block 39 ...
Page 49: ...ETAtouch controller Buffer function block 49 ...
Page 53: ...ETAtouch controller Hot water tank function block 53 ...
Page 57: ...ETAtouch controller Fresh water module function block 57 ...
Page 81: ......
Page 82: ...www eta co at ...
Page 83: ......
Page 84: ...www eta co at ...