Regular cleaning
Check walls of ash collection duct
The walls of the ash collection duct may be white to
brown in appearance. If they are black with soot, either
too much wood was burned at too low a heat consump-
tion, the fire was not lit correctly at start-up or, in very
infrequent cases, the lambda probe gave incorrect
measurement values.
Fig. 10-4: Check walls of ash collection duct
Empty the ash box
Before you empty the ash box, the pellet burner
must be switched off and [Switched off] mode
displayed in its overview window.
If the pellet burner is in heating mode, end it by
pressing the On/Off switch
in the boiler
overview window. The boiler then performs an ember
burnout and switches to [Switched off] mode.
On both sides of the ash box is a tension lock that fixes
the ash box to the boiler. Open both tension locks by
pressing the safety catch in the direction of the arrow.
Fig. 10-5: Opening the latches
Pull the ash box straight out from the front of the boiler.
Fig. 10-6: Removing the ash box
Take off the cover of the ash box by slackening the two
tension locks, and empty the ash box. Check the seal
on the ash box cover to ensure it is in good condition.
Fig. 10-7: Empty ash box, check seal
Check the ash for embers. Never put hot ash into
the waste bin due to risk of fire!
Also check the integrity of the seal on the boiler. If it is
damaged, the boiler can suck in leak air, causing
combustion problems and malfunctions.
Fig. 10-8: Check seal
Summary of Contents for TWIN 20 kW
Page 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Page 39: ...ETAtouch controller TWIN function block 39 ...
Page 49: ...ETAtouch controller Buffer function block 49 ...
Page 53: ...ETAtouch controller Hot water tank function block 53 ...
Page 57: ...ETAtouch controller Fresh water module function block 57 ...
Page 81: ......
Page 82: ...www eta co at ...
Page 83: ......
Page 84: ...www eta co at ...