Emission measurement
TWIN emission measurement
9
measurement and a cool-down time of [Lock
duration] 8 h, the warning notice will appear
starting at 9:00 .
3. The log boiler must be heated up approximately 2
hours before the measurement in order to reach
the permissible operating temperature that is
required for measurement.
4. When the log boiler is ready for emissions mea-
surement, a corresponding message will appear
on the screen. In addition, a countdown for the
emissions measurement will be displayed. The
emission measurement is to be carried out during
this period.
Fig. 2-3: Countdown
No doors on the log boiler may be opened
during the emission measurement. Also, do
not stoke the fire in the log boiler.
5. Switch the boiler back to normal mode after the
emission measurement. To do this, press the
[Deactivate measurement]
button in the
settings window. If you do not press this button, the
boiler will automatically switch back to normal
mode after some time.
2.2
TWIN emission measurement
Prepare and perform emissions measurement
1. The pellet burner must be switched on with the On/
Off
switch. In the boiler overview, press
the [Measurement]
button in order to open the
emissions measurement settings window.
Fig. 2-4: Settings window for emission measurement
2. Use the [Begin measurement]
button to enter
the date agreed for chimney sweeping. The pellet
burner will then start in time to reach the
permissible operating temperature for
measurement purposes. By pressing the [Start
now]
button, the boiler will immediately begin
preparations for a subsequent measurement.
In addition, the locking time of the boiler can be
adjusted (
[Lock duration] button). This relates
to the set time of the measurement. During this
period no heating operation will be started, so that
the heating system has time to cool down.
Example: If a time of 17:00 is set for the emission
measurement and at [Lock duration] 8 h, heating
will end at 09:00 .
3. If the date has been entered, it will appear in the
boiler overview. The boiler will then start in time to
reach the permissible operating temperature for
measurement purposes.
Fig. 2-5: Set date
4. If the boiler is ready for emissions measurement, a
corresponding message will appear on the screen.
In addition, a countdown for the emissions
Summary of Contents for TWIN 20 kW
Page 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Page 39: ...ETAtouch controller TWIN function block 39 ...
Page 49: ...ETAtouch controller Buffer function block 49 ...
Page 53: ...ETAtouch controller Hot water tank function block 53 ...
Page 57: ...ETAtouch controller Fresh water module function block 57 ...
Page 81: ......
Page 82: ...www eta co at ...
Page 83: ......
Page 84: ...www eta co at ...