14
If you chose an address block size of 256 bytes, you can use 32 different
address settings in the range $FE0400 to $FEFC00. For an address block size of
8 KBytes, jumpers B14 and B15 are ignored. This provides only eight address
settings. The default base address of the board is $FE0400.
The following table provides you with an overview of the configuration of
jumpers B2, and B12 to B16 for the base addresses of the 256-byte blocks. "o"
stands for an open jumper; "c" for a closed jumper.
note
A closed jumper means logical "0"; an open jumper means logical "1".
Jumper
Address
Default Setting
B2
A15
Closed
B12
A14
Closed
B13
A13
Closed
B14
A12
Closed
B15
A11
Closed
Tab. 1-1
Assignment of Jumper and Address Line
Address Range
B2
B12
B13
B14
B15
B16
0xFE0400 - 0xFE04FF
c
c
c
c
c
o
0xFE0C00 - 0xFE0CFF
c
c
c
c
o
o
0xFE1400 - 0xFE14FF
c
c
c
o
c
o
0xFE1C00 - 0xFE1CFF
c
c
c
o
o
o
0xFE2400 - 0xFE24FF
c
c
o
c
c
o
0xFE2C00 - 0xFE2CFF
c
c
o
c
o
o
0xFE3400 - 0xFE34FF
c
c
o
o
c
o
0xFE3C00 - 0xFE3CFF
c
c
o
o
o
o
0xFE4400 - 0xFE44FF
c
o
c
c
c
o
0xFE4C00 - 0xFE4CFF
c
o
c
c
o
o
0xFE5400 - 0xFE54FF
c
o
c
o
c
o
0xFE5C00 - 0xFE5CFF
c
o
c
o
o
o
0xFE6400 - 0xFE64FF
c
o
o
c
c
o
0xFE6C00 - 0xFE6CFF
c
o
o
c
o
o
0xFE7400 - 0xFE74FF
c
o
o
o
c
o
Tab. 1-2
Base Address and Jumper Configuration
Summary of Contents for ES1650.1
Page 1: ...ES1650 1 Piggyback Carrier Board User s Guide ...
Page 10: ...Introduction 10 ...
Page 20: ...20 Physical Dimensions Circuit board 100 x 160 mm Front panel Height 3 U Width 4 HP 20 3 mm ...
Page 45: ...45 Physical Dimensions Length 100 mm Width 48 mm Depth 12 mm ...
Page 46: ...46 ...
Page 64: ...PB1650PRT1 1 Prototyping Piggyback 64 ...
Page 82: ...82 ...