ES4100.1 Chassis VME64x - User’s Guide
14
Functional Description
ETAS
2.2
Applications
The ES4100.1 Chassis VME64x is designed to allow the construction of large
VMEbus systems. Its active cooling system makes it suitable also for installing
boards with high heat emission.
The chassis can be combined with all ES4000 series rack systems.
2.3
Mechanical Structure
The ES4100.1 Chassis VME64x is designed with 19" geometry and 4 U front
panel height. The power switch and displays are located on the front panel.
The figure below shows a cut-out section of the chassis.
Fig. 2-2
Cut-out Section of the Chassis
2.4
Display Elements
The front panel of the chassis has six LEDs and a control lamp in the power
switch that show you various operating and error statuses.
CAUTION!
The ES4100.1 Chassis VME64x may be installed and operated by
trained technical personnel only.
Improper installation and operation may damage the chassis and
boards, and may cause a health hazard.
Display
Meaning
Power Switch
Power supply switched on and power voltage applied
Power Fail
The "ACFAIL" of the VME bus is active.
Fan Error
At least one fan has failed.
+5 V
The supply v5 V is active.
+12 V
The supply v12 V is active.
-12 V
The supply voltage -12 V is active.
+3.3 V
The supply v3.3 V is active.
Tab. 2-1
Display on the Front Panel
350,50
L
N
P E
PE
N
L
Summary of Contents for ES4100.1
Page 1: ...ES4100 1 Chassis VME64x User s Guide...
Page 12: ...ES4100 1 Chassis VME64x User s Guide 12 Introduction ETAS...
Page 16: ...ES4100 1 Chassis VME64x User s Guide 16 Functional Description ETAS...
Page 20: ...ES4100 1 Chassis VME64x User s Guide 20 Operation ETAS...
Page 26: ...ES4100 1 Chassis VME64x User s Guide 26 Technical Data ETAS...
Page 28: ...ES4100 1 Chassis VME64x User s Guide 28 ETAS Contact Addresses ETAS...