ES4408.1 Load Chassis - User’s Guide
30
Pin Assignment and Display Elements
ETAS
4.3
“Load 7” Connector
The loads at slot 2 are made accessible at the “Load 7” connector.
Fig. 4-3
“Load7” Connector
Type: Hybrid DSUB 8W8
(male)
The pin assignment is as follows:
Tab. 4-5
Pin Assignment: “Load 7”
A special cable is available for connecting the loads to the PT-LABCAR (“Load7”
connector) (see "“CBAV343.1-1” Cable" on page 44).
Which signals of the relevant load are connected to which signals of the PT-LAB-
CAR is also described in the description of the cable.
Current Rating of the Backplane Pins
Please note the maximum admissible current of 7.5 A (90 V) per backplane pin.
Pin
Signal
Backplane Connector
A1
Load 1+
Slot 2:z18
Slot 2:b18
Slot 2:d18
A2
Load 1–
Slot 2:z20
Slot 2:b20
Slot 2:d20
A3
Load 2+
Slot 2:z22
Slot 2:b22
Slot 2:d22
A4
Load 2–
Slot 2:z24
Slot 2:b24
Slot 2:d24
A5
Load 3+
Slot 2:z26
Slot 2:b26
Slot 2:d26
A6
Load 3–
Slot 2:z28
Slot 2:b28
Slot 2:d28
A7
Load 4+
Slot 2:z30
Slot 2:b30
Slot 2:d30
A8
Load 4–
Slot 2:z32
Slot 2:b32
Slot 2:d32
Housing
ES4408 protective earth
A1 A2 A3 A4 A5 A6 A7 A8