ES4408.1 Load Chassis - User’s Guide
31
ETAS
Pin Assignment and Display Elements
4.4
“Load 8-1” and “Load 8-2” Connectors
The injection loads in slot 0 (“Load 8-2”) and slot 1 (“Load 8-1”) are made
accessible at the “Load 8-1” and “Load 8-2” connectors.
Fig. 4-4
“Load 8-1” and “Load 8-2” Connectors
Type: Hybrid DSUB 8W8
(male)
The pin assignment is as follows:
Tab. 4-6
Pin Assignment: “Load 8-1” (Slot 1)
Pin
Slot:Signal
Backplane Connector
A1
Slot 1:Load 1+
Slot 1:z18
Slot 1:b18
Slot 1:d18
A2
Slot 1:Load 1–
Slot 1:z20
Slot 1:b20
Slot 1:d20
A3
Slot 1:Load 2+
Slot 1:z22
Slot 1:b22
Slot 1:d22
A4
Slot 1:Load 2–
Slot 1:z24
Slot 1:b24
Slot 1:d24
A5
Slot 1:Load 3+
Slot 1:z26
Slot 1:b26
Slot 1:d26
A6
Slot 1:Load 3–
Slot 1:z28
Slot 1:b28
Slot 1:d28
A7
Slot 1:Load 4+
Slot 1:z30
Slot 1:b30
Slot 1:d30
A8
Slot 1:Load 4–
Slot 1:z32
Slot 1:b32
Slot 1:d32
Housing
ES4408 protective earth
A1 A2 A3 A4 A5 A6 A7 A8