ES720.1 - User’s Guide
20
Hardware Description
ETAS
3.4.3
Error and Measuring State of the Module
On the front side of the device are three light-emitting diodes for the display of
the error and measuring state of the module (see Fig. 3-2 on page 18):
•
MEAS
: state of measurement
•
ER
: error state of module
•
MEM
: memory state and memory access
For the display of some states, two or four LEDs are used at the same time (see
table). Fields in the table highlighted with a gray background identify displays of
the LEDs that are not relevant for the description of the respective state.
ON
MEAS
MEM
ER
Description
On
The ES720.1 booted, no valid
license is available.
Flashing
green
(code 1)
Flashing
orange
(code 1)
Flashing
orange
(code 1)
Flashing
red
Power fail restart. The ES720.1
configuration files and the data of
the last recording job can be dam-
aged.
Off
Sufficient storage space (internal
storage/CF card)
On
On
Insufficient storage space (internal
storage/CF card)
On
Off
Warning threshold storage capac-
ity reached (adjustable in the con-
figuration program), available
storage space will be filled shortly
On
Flashing
Connected hardware not ini-
tialised
Off
No measurement
Orange
Measurement, data recording
Flashing
orange
(code 1)
Module ready for measurement,
waiting for trigger event
On
Flashing
orange
(code 1)
Measured variables are written to
the storage connected to the USB
Off
Flashing
orange
(code 1)
Other data is written to the stor-
age connected to the USB (e.g. file
transfer)
3.4.4
State of other Connections
The function state of the USB, I/O and VGA ports is not displayed on the module.
Summary of Contents for ES720.1
Page 1: ...ES720 1 Drive Recorder User s Guide...
Page 22: ...ES720 1 User s Guide 22 Hardware Description ETAS...
Page 34: ...ES720 1 User s Guide 34 Description of Functions ETAS...
Page 56: ...ES720 1 User s Guide 56 Troubleshooting Problems ETAS...
Page 82: ...ES720 1 User s Guide 82 Cable and Accessoires ETAS...
Page 90: ...ES720 1 User s Guide 90 ETAS Contact Addresses ETAS...