Technical Data
ETAS
9
EN_PWR
Output
5 V
state
TTL-compatible, corresponds to operating state of the ES720.1, can be used to
switch on the operating voltage of additional measuring modules:
High = ES720.1 is switched on, Low = ES720.1 is in standby
11 /RPBI
Input
3.3 V
-
TTL-compatible, for connecting an external "Remote Power" button to ground;
function of external "Remote Power" button and "Power" button on the module
is identical
12 PSCI
Input
-
-
TTL-compatible, terminal 15 (Kl.15)
13 IN1
Input
-
-
TTL-compatible, can be used for INCA signals (signal state, trigger) and for ES720.1
recording jobs; sample rate max. 10 Hz
14 IN2
Input
-
-
TTL-compatible, can be used for INCA signals (signal state, trigger);
sample rate max. 10 Hz
15 IN3
Input
-
-
TTL-compatible, can be used for INCA signals (signal state, trigger);
sample rate max. 10 Hz
16 IN4
Input
-
-
TTL-compatible, can be used for INCA signals (signal state, trigger);
sample rate max. 10 Hz
17 GND
-
-
-
Ground
18 GND
-
-
-
Ground
19 LED_ETH
Output
5 V
Status corresponds to the status of the LED
ETH
, dimensioned for direct connecting
Low Current LEDs to ground
20 LED_WLAN
Output
5 V
Status corresponds to the status of the LED
WLAN
, dimensioned for direct con-
necting Low Current LEDs to ground
21 LED_PWR
Output
5 V
Status corresponds to the status of the LED
ON
, dimensioned for direct connecting
Low Current LEDs to ground
22 LED_MEAS
Output
5 V
Status corresponds to the status of the LED
MEAS
, dimensioned for direct connect-
ing Low Current LEDs to ground
Pin Signal
Type
Logic
I max.
[mA]
Meaning
Summary of Contents for ES720.1
Page 1: ...ES720 1 Drive Recorder User s Guide...
Page 22: ...ES720 1 User s Guide 22 Hardware Description ETAS...
Page 34: ...ES720 1 User s Guide 34 Description of Functions ETAS...
Page 56: ...ES720 1 User s Guide 56 Troubleshooting Problems ETAS...
Page 82: ...ES720 1 User s Guide 82 Cable and Accessoires ETAS...
Page 90: ...ES720 1 User s Guide 90 ETAS Contact Addresses ETAS...