5
Installation
This chapter contains information about the following topics:
• Connection to the ECU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
• Connecting to the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
• Connection to the Debugger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5.1
Connection to the ECU
For connecting the ETK-S20.1 to the ECU the ETK two adapters are recom
-
mended:
• at CON1 adapter ETAL1 and
• at CON2 adapter ETAL2 or ETAL3.
The suitable connector SAMTEC bit "TMF-105" should have been populated
onto the ECU PCB for adapter ETAL1.
CAUTION
Some components of the interface board may be damaged or destroyed by
electrostatic discharges. Please keep the board in its storage package until it
is installed.
The board should only be taken from its package, configured, and installed at
a work place that is protected against static discharge.
CAUTION
Risk of short circuiting the internal signals of the ETK!
When you mount the ETK to the ECU, you must ensure that the screws and
washers used will not penetrate the ETK printed circuit board.
NOTE
The ETAL1 adapter and the ETAL2/ ETAL3 adapter need to be ordered sepa
-
rately (refer chapter “Ordering Information” on page
59).