Output Channel Control Switches
Each output channel on the ArcLamp Driver is controlled by a switch block (S1–S4, shown
below). Switch positions 2–5 are factory set to allow individual control of each output. In order
to bridge channels together, you must adjust the positions of switches 2–5.
LED OUT 1
LED OUT 2
LED OUT 3
LED OUT 4
S1
S2
S3
S4
Switch
blocks
CH 1
CH 2
CH 3
CH 4
S1
S2
S3
S4
Switch
blocks
S
1
S2
S3
S4
ArcLamp Driver 150
Wall-Mount ArcLamp Driver 350/
Wall-Mount ArcLamp Driver 700
S1
S2
S3
S4
CH 1
CH 2
CH 3
CH 4
S1
S2
S3
S4
Switch
blocks
Rack-Mount ArcLamp Driver 350/
Rack-Mount ArcLamp Driver 700
Switch Blocks
Each of the four switch blocks controls one output channel.
•
Switch block S1 controls the output channel labeled "LED OUT 1" on ArcLamp Driver 150
or "CH 4" on ArcLamp Driver 350 and 700.
•
Switch block S2 controls the output channel labeled "LED OUT 2" on ArcLamp Driver 150
or "CH 3" on ArcLamp Driver 350 and 700.
•
Switch block S3 controls the output channel labeled "LED OUT 3" on ArcLamp Driver 150
or "CH 2" on ArcLamp Driver 350 and 700.
•
Switch block S4 controls the output channel labeled "LED OUT 4" on ArcLamp Driver