ArcSystem Installation Manual
Luminaire Connection to Driver
ArcSystem Pro One-Cell luminaires connect to a driver using Molex receptacles labeled "LED
Head" for D1 and D2 Series Drivers and "LED" followed by output channel number for D4 Series
drivers. All D1 Series and D2 Series drivers and some models of D4 Series drivers have Molex
receptacles for ArcSystem Pro One-Cell luminaire connections. Models of D4 Series drivers with
two-pin terminal outputs can be used to provide power and data to other fixtures.
Note:
Maximum supported wire length between One-Cell luminaires and D1 Series
and D2 Series drivers is 15 m (49 ft).
Maximum supported wire length between any load and a D4 Series driver is 10 m
(33 ft).
1.
Install the ceiling with the prepared mounting hole for the luminaire.
2.
Run the luminaire cable through the previously installed screw-clamp conduit connector at
one of the driver knockouts.
Two-pin terminal wiring
Line
Neutral
Line
Neutral
Line
Neutral
Line
Neutral
3.
Connect the luminaire cable to the driver
output.
•
D1 Series, D2 Series, and D4 Series
Drivers with Molex receptacles: connect
the four-pin luminaire cable(s) to the Molex
receptacle(s) inside the driver. See
the Driver and Luminaire on page 19
.
Support the luminaire(s). Do not let
luminaires hang by their cables.
•
D4 Drivers with terminal outputs: wire
loads (luminaires) to a provided two-pin
connector and insert the connector into a
two-pin terminal inside the driver. See the
illustration at right.
-
Constant Current (CC) drivers: verify
that each output channel's current
output is configured correctly. See
D4 Series Driver Current Configuration on
.