48
ArcSystem Installation Manual
Preparing for Installation
Note:
Mounting hardware and installation location must support the TX1 Transmitter,
conduit hardware, and all cable required for installation.
Supplies
The TX1 Transmitter includes four #10 mounting screws.
The following supplies are required, but not provided, for TX1 Transmitter installation:
•
½ in conduit and conduit fittings
•
Phillips head screw driver
•
Four each wall anchors, as needed
Electrical and Wiring Specifications
The TX1 Transmitter accepts 100–240 VAC, 50/60 Hz power input. ETC recommends installing
all wiring in grounded metal conduit.
Wire and Terminal Specifications
Terminal / Connector
Conduit
Entry
Wire Range / Specification
Strip Length
Torque
power input
(hot/neutral/ground)
½ in
conduit
up to 10 AWG (solid or stranded)
(up to 6 mm
2
)
7 mm
(1/4 in)
0.5 Nm
(4 in-lb)
AUX contact inputs
(input 1/input 2/ground)
½ in
conduit
22–14 AWG (solid or stranded)
(0.6–1.6 mm
2
)
5 mm
(3/16 in)
0.5 Nm
(4 in-lb)
DMX in/out terminals
½ in
conduit
Belden 9729 (or equivalent)
See
.
Mounting
The TX1 Transmitter can be set on a flat horizontal surface, such as a table top, or surface-
mounted using the four holes located on the back side of the enclosure.
1.
Remove the two screws securing the front of the TX1 to the enclosure.
•
Save these screws for reinstallation later.
•
The cover is tethered to the enclosure. Be careful when handling.
2.
Align the TX1 to the installation location and secure it in place using the four #10 screws
provided.
3.
The TX1 enclosure has three conduit knockouts. As required by local code, remove the
knockouts and attach conduit.
Note: