Standard System One-Cell Installation
21
Power
Internal wire colors vary by model.
Factory Wire Colors
Model
Color
Type
North America
and Europe
green/yellow
ground/earth
North America
black
line/hot
North America
white
neutral
Europe
brown
live
Europe
blue
neutral
Perform the following steps to wire power to the driver.
WARNING:
Circuits that are installed without an accessible power
disconnect device cannot be serviced or operated safely.
AVERTISSEMENT :
Il est imprudent d'utiliser ou de réparer les circuits
installés sans qu'un dispositif de déconnexion de l'alimentation ne soit
accessible.
1.
Make sure power is off at the main circuit breaker.
2.
See
Wire and Terminal Specifications on page 16
for specification of wire, strip length,
and terminal torque ratings. Prepare the wires accordingly.
3.
Loosen the three screw terminals for NEUTRAL (N), GROUND (
), and LINE (L)
connections.
4.
Insert the ground wire (typically green) into the GROUND (
) terminal and tighten the
screw.
5.
Insert the neutral wire (typically white) into the NEUTRAL (N) terminal and tighten the
screw.
6.
Insert the line wire (typically black) into the LINE (L) terminal and tighten the screw.
7.
Tug gently on the wires to ensure they are secure.