background image

Page 1

ELED2(H) Installation Guide

Installation Guide

 

ELED2(H)

Tunable White Dimming Controller

• 

CAUTION

 - This equipment has more than one 

power supply connection point.  To reduce the risk 
of electric shock, disconnect both the branch circuit- 
breakers or fuses and emergency power supplies 
before servicing.
• 

CAUTION

 – Risk of Electric shock hazard. The 

controller uses high voltage and should only be in-

stalled by  qualified personnel in accordance with 

National Electrical Code and any local regulations.
• 

CAUTION

 - To avoid electrical overload, total 

connected load should not exceed output rating.
• 

This product is suitable for use in dry locations 

where the ambient temperature is  -5°C  to  +50°C 
(23°F to 122°F).
• 

Do not use outdoors.

• 

Do not mount near gas or electric heaters

• 

Equipment should be mounted in locations and 

at heights where it will not be subjected to 

SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS 

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS

Summary of Contents for Echoflex ELED2

Page 1: ...voltage and should only be in stalled by qualified personnel in accordance with National Electrical Code and any local regulations CAUTION To avoid electrical overload total connected load should not exceed output rating This product is suitable for use in dry locations where the ambient temperature is 5 C to 50 C 23 F to 122 F Do not use outdoors Do not mount near gas or electric heaters Equipmen...

Page 2: ...horized personnel The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition Do not use this equipment for other than its intended use Servicing should be performed by qualified ser vice personnel Pollution Degree 2 ...

Page 3: ...mple Tap technology is included allowing installers and facility operators to manage configuration settings without any specialized tools see wiring diagram on page 5 for detailed output load ratings Preparing To Install The Controller The controller should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel The controller is mounted using t...

Page 4: ...power to the circuit 7 If the controller was pre commissioned you can use one of the pre linked devices to test the controller operation If the controller was not pre commissioned by the factory refer to the section of this guide titled Linking the First Switch Use this switch to verify the controller functionality i Note Always follow applicable NEC and local electrical code requirements when ins...

Page 5: ...ill be a color that correlates to the channel Red CH1 Green Ch2 Blue Set point Press the LEARN button to scroll through the channels 2 When linking a wall switch press the switch paddle ON three times Tunable White Dimming Controller Power LED Clear Button Learn Button Learn LED Antenna orange Do not cut or cap Black Line 120 277VAC OR 240 347VAC 50 60 Hz 500 mW max White Neutral Red Load switched...

Page 6: ...es To return the controller to the factory pre commissioned state press the CLEAR button until the red POWER and green LEARN LEDs start blinking approximately 5 seconds Release the button and the red POWER LED will begin blinking indicating the factory commissioned pre linked devices To completely clear the controller returning it to factory default settings removing all linked devices press the C...

Page 7: ...mber of devices linked This pattern will repeat after a short pause See the ELED2 programming guide for more information https www echoflexsolutions com files 8DC 5884 ELED2 Programming Guide pdf The table below describes the number of LED blinks for each device type Dimming Channel 1 RED POWER LED Blink Codes Factory Default ON Solid switch es 1 long blink followed by short blinks counting switch...

Page 8: ...Std E60730 UL 2043 Plenum rated California Energy Commission Title 24 CEC Washington State Energy Code WSEC ANSI ASHRAE IES Standard 90 1 International Energy Conservation Code IECC New York City Energy Conservation Code NYCECC FCC Part 15 231 Contains FCC ID SZV STM300U IC RSS 210FCC Part 15 231 Contains FCC ID SZV STM300U The enclosed device complies with Part 15 of the FCC Rules Operation is su...