Fire prevention:
1.
AR 250
utilizes a Philips MSD 250W/2 lamp or equivalent; the use of any other lamp is not recommended and will null and void
the fixture’s warranty.
2.
Never locate the fixture on any flammable surface.
3.
Minimum distance from flammable materials: 0.5m (1.6’).
4.
Minimum distance from the closest illuminable surface: 2.0m (6.6’).
5.
Replace any blown or damaged fuses only with those of identical values. Refer to the schematic diagram if there is any doubt.
6.
Connect the projector to mains power via a thermal magnetic circuit breaker.
Prevention against electric shock
1. High voltage is present in the internals of the unit. Isolate the projector from mains supply prior to performing any function which
involves touching the internals of the unit, including lamp replacement.
2.
For mains connection, adhere strictly to the guidelines outlined in section 7 of this manual.
3.
The level of technology inherent in the
AR 250
requires the use of trained technicians
4.
A good earth connection is essential for proper function of the projector.
Never operate the unit without proper earth connection.
Protection against ultraviolet radiation
1.
Never turn on the lamp if any of the lenses, filters, or the housing is damaged; their respective functions will only operate efficiently
if they are in perfect working order.
2.
Never look directly into the lamp when it is operating.
Safety:
1.
The projector should always be installed with bolts, clamps, and other fixings which are sufficiently rated to support the weight
of the unit.
2.
Always use a secondary safety chain of a sufficient rating to sustain the weight of the unit in case of the failure of the primary
fixing point.
3.
The external surface of the unit, at various points, may exceed 150°C (302ºF).
Warning: Never handle the unit until at least 10 minutes after the lamp is turned off.
4.
Never install the fixture where unauthorised and untrained personnel may tamper with it.
5.
Always replace the lamp if any physical damage is evident.
6.
Never install the fixture in an enclosed area lacking sufficient air flow; the ambient temperature should not exceed 35°C (95.0ºF).
7.
A hot lamp may explode. always wait for at least 10 minutes to elapse after the unit has been turned off prior to attempting to
replace the lamp.
Always wear suitable hand protection when handling the lamp.
Protection rating of the body against liquids and solids:
1. The fixture has an IP 44 protection rating; this indicates that a particle larger than 1mm (.04”) cannot penetrate the unit and that it
is totally protected against showers of water.
The protection rating allows the fixture to be utilized in an exposed location in inclement weather as long as it is installed according
to the instructions located in section
7.2 “Installing the unit in exposed areas”
.
3. Important safety information
5
English
Summary of Contents for Irideon AR250