Irideon WLZ User Manual
7
From a DMX/RDM source
Data – (Blac
k)
Data + (Red)
Belden 9729 (or equivalent) wire
termination to screw connector
4 to 8 = n/c
COM
If using Belden 9729:
a. See the
DMX Cable
Preparation for Screw
Termination Setup Guide for
instructions to prepare and
terminate Belden 9729 for
DMX input cable to the screw
terminal connector.
b. Install the screw terminal
connector with wires
terminated to the DMX/RDM
Input receptacle on the
termination board.
Data – (ORG)
Data + (W
/ORG
)
Cat5 (or equivalent) wire
termination to IDC connector
COM
BRN
GRN
W/GRN
BLU
W/BLU
If using Category 5:
a. See the
Cat5 Cable Preparation
for IDC Termination Setup
Guide for instructions to
prepare and terminate
Category 5 for DMX/RDM input
cable to the insulation
displacement connector.
b. Install the IDC connector with
wires terminated to the
DMX/RDM Input receptacle on
the termination board.
4. Optionally, terminate DMX/RDM thru to the next device in the DMX
data run. Up to 32 DMX/RDM devices can be daisy-chained
together per data run.
a. See the specific termination setup guide for the type of cable
used (either Belden 9729 or Category 5) in the installation.
Termination kits are ordered separately.
b. Install the connector with wires terminated to the DMX/RDM
Thru receptacle on the termination board.