background image

4  • Source Four MultiPAR

Accessories

Changing Source Four MultiPAR lenses

Removing a lens

1.

Disconnect power from the fixture before attempting to remove or install a lens.

2.

Source Four MultiPAR lenses become hot while in operation. Let the fixture cool 
before handling the lens.

3.

Place the fixture on a flat, stable work surface.

4.

Tilt the front of the fixture down at least 45 degrees.

5.

Press one (or both) of the spring clips with your finger(s) to release the lens. 
(

Figure 2

). 

6.

Allow the lens to drop forward from under the clip. 

7.

When the lens drops, remove your finger, maintain pressure on the clip while 
sliding your finger(s) off the clip. Allow the lens to slide forward until you can grip 
it securely.

8.

Carefully remove the lens from the fixture. 

Installing a lens

1.

Position the fixture with the front of the unit (the lens side) facing you, and tilted 
up slightly (

Figure 3

).

2.

Hold the lens by the edge, and position it so the convex side faces the back of 
the fixture 

Figure 4

.

N o t e :

Installing the lens with the convex side out will not impair the 

optics, but it will make removing the lens more difficult.

3.

From the top of the fixture, slide the lens behind one of the lens clips and into the 
cast metal lens channel. 

4.

Gently push the top of the lens inward until it snaps behind the other lens clip

C A U T I O N :

Never operate the Source Four MultiPAR without a lens 

in place.

Change lenses if they become cracked or badly 

scratched.

ETC Part #

Color frame 7.5 in. sq./6.7 in. inside diameter)

7061A3047

Safety cable (31 in.)

7060A1022

C-clamp

7060A2009

Very Narrow Spot lens

7061A4002

Narrow Spot lens

7061A4003

Medium Flood lens

7061A4005

Wide Flood lens

7061A4006

Set of four Source Four PAR lenses

 

(VNSP, NSP, MFL, WFL)

7061A1013

Figure 2

Figure 3

Figure 4

 

ORDER DIRECTLY TODAY AT: 

www.BulbAmerica.com

 or CALL TOLL FREE 888-505-2111 

Summary of Contents for Source Four MultiPAR

Page 1: ...e provided with each MultiPAR Be certain to secure the MultiPAR to the batten by threading the safety cable through the end cap holes when hanging the unit Power requirements The Source 4 MultiPAR has several different standard as well as custom configura tions of electrical circuitry Make certain you are familiar with the wiring of the Multi PAR and that you have sufficient power dimmer capacity ...

Page 2: ...e operation 6 Insert lamp base into pin holes in socket assembly 7 Push down on the lamp base until the lamp is firmly inserted Make sure that the lamp is fully seated with the bottom of the lamp heat sink flush to the socket assembly surface 8 To reinstall the socket assembly insert until the heat sink base rests flush against the reflector then tighten the knurled bolt to secure the socket assem...

Page 3: ...300 hour HPL 575 120X 575 120 3 050ºK 2 000 hour HPL 575 230 575 230 3 200ºK 400 hour HPL 575 230X 575 230 3 050ºK 1500 hours HPL 575 240 575 240 3 200ºK 400 hour HPL 575 240X 575 240 3 050ºK 1500 hours HPL 750 115 750 115 3 250ºK 300 hours HPL 750 115X 750 115 3 050ºK 1000 hours HPL 750 120 750 120 3 050ºK 2 000 hour HPL 750 120X 750 120 3 050ºK 2 000 hour HPL 750 230 750 230 3 200ºK 300 hours HP...

Page 4: ...the unit the lens side facing you and tilted up slightly Figure 3 2 Hold the lens by the edge and position it so the convex side faces the back of the fixture Figure 4 Note Installing the lens with the convex side out will not impair the optics but it will make removing the lens more difficult 3 From the top of the fixture slide the lens behind one of the lens clips and into the cast metal lens ch...

Page 5: ...to step 5 5 Dampen a clean soft lint free cotton cloth with a mild soapy water solution and gently wipe the reflector 6 Remove any soapy water residue with a clean soft lint free cotton cloth dampened with water 7 Reinstall a lens before using the fixture CAUTION Do not use glass or window cleaners on the reflector Chemicals in the cleaners will harm the reflective coating Do not use paper towels ...

Page 6: ... insert the wires labeled 1 4 7 10 4 In the second terminal block from the left insert the wires labeled 2 5 8 11 5 In the third terminal block from the left insert the wires labeled 3 6 9 12 6 The fourth terminal block from the left is not used and is left empty See Figure 7 for detail Figure 7 Four circuit configuration 1 Disconnect power before changing the wiring 2 Loosen the captured screw on...

Page 7: ...mbly 16 AWG Wire Silver Contact 3 5 or 7ft long 2 2 W330 02 TP22 CLCM assembly ceramic 1 3 W330 03 TP22 CLCM assembly mica 1 1 6 7061A2027 Lamp Burner Assembly 3ft 1 1 6 7061A2028 Lamp Burner Assembly 5ft 1 1 6 7061A2029 Lamp Burner Assembly 7ft 1 6 7061A3061 Thumbscrew 1 7 various HPL lamp 1 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111 ...

Page 8: ...K mail etceurope com Asia mail etcasia com Service service etcconnect com Toll free 800 775 4382 Comments about this document techcomm etcconnect com Copyright 2002 Electronic Theatre Controls Inc All Rights Reserved Product information and specifications subject to change 7061M1014 Rev B Released 2 03 Spare parts list Source Four MultiPAR Final Assembly Reference Number Part Number Description Qu...

Reviews: