8
P-TS7 User Manual
Note:
The firmware version in the touchscreen must be compatible with the
firmware version in the Paradigm Processor for the two devices to communicate.
• Memory Usage the “Memory Usage” section displays the “Total” memory available, the
memory “Used” and the available memory that is “Free” for use.
• Boot Reason the last action that caused the touchscreen to boot. Reasons for reboot
could be due to a [Reset] button press on the touchscreen I/O panel, power loss, etc.
• Watchdog displays the status of the Watchdog service.
Note:
Watchdog is a service that monitors touchscreen activity and will
automatically reboot the device in the event it would suffer a crash or lockup.
Watchdog should be enabled unless instructed otherwise by ETC Technical Services.
Screen
The Screen page provides user level settings for the touchscreen including:
• Backlight Level a level bar is provided to set the relative brightness of the touchscreen
backlight. By default, the level is set to full.
Note:
On touchscreen models with a light sensor, the Backlight Level sets the
maximum level of brightness.
• Backlight Timeout sets the length of inactivity time before the backlight fades to its
backlight timeout level. This is separate from any configuration related Inactivity Timeout
settings.
• Level the intensity level the backlight will fade to when its
Backlight Timeout
has been
reached. This level can be set to either “Off” or “Dim”.
Note:
Light and Proximity Sensors are not available on all P-TS7 touchscreen models.
Summary of Contents for Unison Paradigm P-TS7
Page 31: ...Cleaning the Display 27 ...