7.3 Floor Installation
Select
the appropriate mounting height when installing the
solar photovoltaic module,
in order to clean up the snow, dust and other coverings on the module surface. In
addition, prevent the lower half of the module being covered by snow for a long time
in the winter.
Ensure that the lowest portion of the module is placed high enough so that it is not
shaded by plants or trees or damaged by flying sand.
7.4
Installed on Roof for Building
The modules have been tested and have passed fire test type-1 (UL).
The fire rating of this module is valid only when mounted in the manner specified in
the mechanical mounting instructions
When installed on a roof, check building codes to ensure that the required modules
installed in buildings and structures (roofs, appearance, bearing, etc.) have sufficient
loading capacity. When installing the module, ensure that the module is installed in a
fireproof roof, and the slope of the roof is less than 5in/ft to ensure maintaining a fire
class rating.
When installing a module on a roof or building, ensure that it is securely fastened and
cannot fall as a result of wind or snow loads.
Leave sufficient space at the back of the module to ensure proper ventilation for the
cooling module
(
a minimum distance of 10 cm between the module and the mounting
surface).
When installing a module on a roof, any roof penetration required to mount the
module must be properly sealed to prevent leaks.
When the wind is strong, DO NOT work on the roof or building to prevent accidents.
In some conditions, you may need to use special brackets; please consult a reputable
solar installer or systems integrator.
8
Mechanical Installation
The module is considered to be in compliance with UL 1703 only when the module is
mounted in the manner specified by the mounting instructions below.
8.1 Mounting with Clamp
On the long frame of module, the modules use the clamps to mount onto the support
structure. The positions of installation must be located according to Figure 8.1. Design