                                              Installation and Safety Manual of CIGS-3000A1&E1 Solar Photovoltaic Module

 

 

 
This document and all information contained herein is the sole property of ETERBRIGHT SOLAR CORPORATION and shall not be distributed, reproduced, or 
disclosed in whole or in part without the prior written consent of ETERBRIGHT SOLAR CORPORATION. 

A3-224

 

7.3 Floor Installation 

 

Select 

the appropriate mounting height when installing the 

solar photovoltaic module, 

in order to clean up the snow, dust and other coverings on the module surface. In 
addition, prevent the lower half of the module being covered by snow for a long time 
in the winter. 

 

Ensure that the lowest portion of the module is placed high enough so that it is not 
shaded by plants or trees or damaged by flying sand. 

 

7.4

 

Installed on Roof for Building 

 

The modules have been tested and have passed fire test type-1 (UL). 

 

The fire rating of this module is valid only when mounted in the manner specified in 
the mechanical mounting instructions 

 

When installed on a roof, check building codes to ensure that the required modules 
installed in buildings and structures (roofs, appearance, bearing, etc.) have sufficient 
loading capacity. When installing the module, ensure that the module is installed in a 
fireproof roof, and the slope of the roof is less than 5in/ft to ensure maintaining a fire 
class rating. 

 

When installing a module on a roof or building, ensure that it is securely fastened and 
cannot fall as a result of wind or snow loads. 

 

Leave sufficient space at the back of the module to ensure proper ventilation for the 
cooling module

(

a minimum distance of 10 cm between the module and the mounting 

surface). 

 

When installing a module on a roof, any roof penetration required to mount the 
module must be properly sealed to prevent leaks. 

 

When the wind is strong, DO NOT work on the roof or building to prevent accidents. 

 

In some conditions, you may need to use special brackets; please consult a reputable 
solar installer or systems integrator. 

 

8

 

Mechanical Installation 

The module is considered to be in compliance with UL 1703 only when the module is 
mounted in the manner specified by the mounting instructions below. 

 

8.1 Mounting with Clamp 

 

On the long frame of module, the modules use the clamps to mount onto the support 
structure. The positions of installation must be located according to Figure 8.1. Design 

Summary of Contents for CIGS-3000A1 Series

Page 1: ...N AND SAFETY MANUAL for CIGS 3000A1 and CIGS 3000E1 Solar Photovoltaic Modules Release Date 2019 6 20 Version 1 2 CIGS 3000A1 Series CIGS 3000A1 CIGS 3050A1 CIGS 3100A1 CIGS 3150A1 CIGS 3200A1 CIGS 32...

Page 2: ...stributed reproduced or disclosed in whole or in part without the prior written consent of ETERBRIGHT SOLAR CORPORATION A3 224 Contents 1 Introduction 2 Disclaimer of Liability 3 General Information 4...

Page 3: ...ponsibility is assumed by ETERBRIGHT SOLAR CORPORATION for any infringement of patents or other rights of third parties which may result from the use of the PV product No license is granted by implica...

Page 4: ...bjects on the module Do not drop the module heavily 5 2 Installation Safety DO NOT DISCONNECT UNDER LOAD COMPLETELY cover the module with an opaque material during installation to prevent electricity...

Page 5: ...t PMPP A 5 51 5 57 5 63 5 69 5 75 Module models CIGS 3250A1 CIGS 3300A1 CIGS 3350A1 CIGS 3400A1 CIGS 3450A1 Minimum power PMPP W 325 330 335 340 345 Power tolerance 5 3 5 3 5 3 5 3 5 3 Open circuit vo...

Page 6: ...V 73 1 73 3 73 5 73 6 73 8 Short circuit current ISC A 6 67 6 69 6 71 6 73 6 75 Voltage at PMPP V 55 9 56 2 56 5 56 9 57 1 Current at PMPP A 5 81 5 87 5 93 5 98 6 04 Module models CIGS 3500E1 CIGS 355...

Page 7: ...Module models CIGS 3000A1 CIGS 3050A1 CIGS 3100A1 CIGS 3150A1 CIGS 3200A1 Minimum power PMPP W 220 8 224 6 228 4 232 2 236 0 Open circuit voltage VOC V 67 9 68 1 68 3 68 4 68 6 Short circuit current...

Page 8: ...250E1 CIGS 3300E1 CIGS 3350E1 CIGS 3400E1 CIGS 3450E1 Minimum power PMPP W 239 7 243 5 247 3 251 2 254 9 Open circuit voltage VOC V 68 7 68 9 69 1 69 2 69 4 Short circuit current ISC A 5 34 5 35 5 37...

Page 9: ...ance Level 6 3 Thermal Characteristics NMOT 46 2 2 Temperature Coefficient of Isc 0 01 K Temperature Coefficient of Voc 0 27 K Temperature Coefficient of Pmax 0 28 K 6 4 Mechanical Data Dimension L W...

Page 10: ...IGHT SOLAR CORPORATION A3 224 IP Rating of Junction Box IP67 Adhesive of Junction Box Silicone Gel Connectors MC4 or Compatible Connectors Cables Section 4 0mm2 12AWG Length 1200mm 6 5 Bypass Diode Ty...

Page 11: ...l tilt angle of the information for the installation refer to the Tilt Angle Selection or consult a reliable solar systems integrator Do not install the module in a location where it would be easy to...

Page 12: ...in buildings and structures roofs appearance bearing etc have sufficient loading capacity When installing the module ensure that the module is installed in a fireproof roof and the slope of the roof i...

Page 13: ...th the requirements of UL 1703 unless the module is mounted with hardware that has been tested and evaluated with the module under this standard or by a field Inspection certifying that the installed...

Page 14: ...t be distributed reproduced or disclosed in whole or in part without the prior written consent of ETERBRIGHT SOLAR CORPORATION A3 224 Recommended minimum clamp dimension mm as in following diagrams To...

Page 15: ...ion Under normal conditions a photovoltaic module is likely to produce more current and or voltage than reported under standard test conditions Accordingly the values of Isc and Voc marked on this mod...

Page 16: ...cording to local regulations e g the NEC National Electric Code in the United States If the building is already equipped with an exterior lightning protection system the PV installation must be integr...

Page 17: ...r grounding connections in accordance with the instructions provided with the module 9 3 Electrical Wiring The cables have connectors for an electrical connection system The module cables should be fi...

Page 18: ...connections every six months or shorter to verify that they are clean secure undamaged and free of corrosion When replacement parts are required the installer or servicer should ensure that parts uses...

Page 19: ...2Revision History Version Details Release Date A Initial Release 2015 09 09 B Add Power Grade 2015 09 25 C 1 Correct 6 3 thermal characteristics and 6 4 front cover 2 Update 6 6 Module Physical Specif...