6.1Electrical Characteristics
A. At Standard Test Conditions(STC)
*1
Module models
CIGS-3000A1
CIGS-3050A1
CIGS-3100A1
CIGS-3150A1
CIGS-3200A1
Minimum power (P
MPP
) [W]
300
305
310
315
320
Power tolerance [%]
+5/-3
+5/-3
+5/-3
+5/-3
+5/-3
Open circuit voltage (V
OC
) [V]
72.3
72.5
72.7
72.8
73.0
Short circuit current (I
SC
) [A]
6.56
6.58
6.60
6.62
6.64
Voltage at P
MPP
[V]
54.4
54.8
55.1
55.4
55.7
Current at P
MPP
[A]
5.51
5.57
5.63
5.69
5.75
Module models
CIGS-3250A1
CIGS-3300A1
CIGS-3350A1
CIGS-3400A1
CIGS-3450A1
Minimum power (P
MPP
) [W]
325
330
335
340
345
Power tolerance [%]
+5/-3
+5/-3
+5/-3
+5/-3
+5/-3
Open circuit voltage (V
OC
) [V]
73.1
73.3
73.5
73.6
73.8
Short circuit current (I
SC
) [A]
6.67
6.69
6.71
6.73
6.75
Voltage at P
MPP
[V]
55.9
56.2
56.5
56.9
57.1
Current at P
MPP
[A]
5.81
5.87
5.93
5.98
6.04
Module models
CIGS-3500A1
CIGS-3550A1
CIGS-3600A1
CIGS-3650A1
CIGS-3700A1
Minimum power (P
MPP
) [W]
350
355
360
365
370
Power tolerance [%]
+5/-3
+5/-3
+5/-3
+5/-3
+5/-3
Open circuit voltage (V
OC
) [V]
73.9
74.0
74.1
74.3
74.5
Short circuit current (I
SC
) [A]
6.95
6.96
6.96
6.96
6.96
Voltage at P
MPP
[V]
55.6
56.3
57.0
57.5
58.1
Current at P
MPP
[A]
6.30
6.31
6.32
6.35
6.37
Module models
CIGS-3750A1
Minimum power (P
MPP
) [W]
375
Power tolerance [%]
+5/-3
Open circuit voltage (V
OC
) [V]
74.8
Short circuit current (I
SC
) [A]
6.98
Voltage at P
MPP
[V]
58.7
Current at P
MPP
[A]
6.39