Installation Instructions and Care
6
If in doubt, consult a qualified electrician.
Help Line
Tel:
01933 673 144
Fax:
01933 678 083
Email:
sales@eterna-lighting.co.uk
For all other information visit our website
www.eterna-lighting.co.uk
Issue 091209_1BT
If you experience problems...
If your light is defective or develops a fault, please return it to the place where you bought it. You can call our
Helpline for advice. The Helpline will gladly give advice on any aspect of any Eterna Lighting product but may
not be able to give specific instructions regarding individual installations.
Eventually, you may want to replace this light fitting
When your light fitting comes to the end of its life or you choose to update or upgrade it by replacing
it, please do not dispose of it with your normal household waste, please recycle where facilities
exist. When you need to dispose of this fitting, check with your retailer or local authority for suitable
options. New regulations require the recycling of Waste from Electrical and Electronic Equipment
(European “WEEE Directive” effective August 2005—UK WEEE Regulations effective 2nd January 2007).
Environment Agency Registered Producer: WEE/GA0248QZ
Safety Markings:
Cleaning
Disconnect the power and clean the exterior only of
this fitting with a moist (not wet) cloth.
Do not use any chemical or abrasive cleaners
Lamp Replacement:
1. Switch off electricity at mains.
2. Turn the three clips outwards to remove the diffuser.
3. Pull the lamp straight out of the gear tray inside.
4. Press the new lamp into position, take care to
position the lamp correctly over the lampholder.
5. Replace the diffuser, take care to position the inside
rim of the diffuser over the circumference of the
rear half of the fitting and the soft seal around the
hole in the diffuser of the PIR detector lens.
6. Press the diffuser in position and turn the three clips
to retain.
7. Restore the power and switch on.
Replacement lamp type:
Wattage:
28W
Size/Type:
GR10q 4pin DD CFL
IP44